MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/clinchem/hvae163

Медицинская библиотека · Clinical chemistry · 2025

Xylazine Pharmacokinetics in Patients Testing Positive for Fentanyl and Xylazine.

Lin Yanchun, Farnsworth Christopher W, Azimi Vahid, Liss David B, Mullins Michael E, Crews Bridgit O

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The increasing prevalence of xylazine in the illicit drug supply is a growing concern for major health consequences in individuals who use fentanyl mixed with xylazine, but limited data are available regarding the pharmacokinetics of xylazine in humans.

METHODS

Xylazine was quantified in serial remnant plasmas collected from 28 patients starting at the initial patient encounter and continuing for up to 52 h from presentation, using LC-MS/MS to calculate the terminal half-life for xylazine. Xylazine metabolites were identified by product ion scanning, and multiple reaction monitoring was used to estimate the relative abundance of xylazine metabolites in 74 collected plasma samples.

RESULTS

The median terminal half-life for xylazine was calculated to be 12.0 h (range: 5.9-20.8). Oxo-xylazine and sulfone-xylazine metabolites were detected in all plasma specimens that contained xylazine.

CONCLUSIONS

The half-life of xylazine in humans is longer than previously observed in animal studies, which furthers the current understanding of the expected duration of effects in individuals who use fentanyl mixed with xylazine and the window of detection. Both oxo-xylazine and sulfone-xylazine appear to circulate in plasma for as long as xylazine.

Для цитирования: Lin Yanchun, Farnsworth Christopher W, Azimi Vahid, Liss David B, Mullins Michael E, Crews Bridgit O. Xylazine Pharmacokinetics in Patients Testing Positive for Fentanyl and Xylazine.. Clinical chemistry. 2025. DOI: 10.1093/clinchem/hvae163.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.