Collagen-sensitive dual-energy-CT as a quantitative tool for tendinopathy assessment: a prospective diagnostic accuracy study.

Diekhoff Torsten, Kim Suchung, Gwinner Clemens, Winkler Tobias, Stoeckle Ulrich, Perka Carsten, Halfter Finn, Mews Jürgen, Hamm Bernd, Lerchbaumer Markus Herbert

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The purpose of this study was to evaluate the effectiveness of collagen-sensitive dual-energy computed tomography (DECT) as a quantitative imaging tool for the assessment and monitoring of load-induced tendinopathy in the Achilles and patellar tendons, comparing it to magnetic resonance imaging (MRI).

METHODS

In a prospective study, 15 consecutive patients clinically diagnosed with Achilles or patellar tendinopathy underwent bilateral DECT and MRI at baseline and 6 months. Quantitative measurements included collagen density assessed via DECT and signal intensity via MRI. Clinical symptoms were evaluated using numerical pain ratings and VISA-A/P scores. The diagnostic accuracy of both imaging modalities was assessed using ROC analysis, and correlations between DECT and MRI findings were investigated.

RESULTS

DECT revealed significantly lower collagen densities on corresponding maps in affected tendons (n = 18, 23.7 ± 20.2) compared to unaffected tendons (n = 12, 60.2 ± 29.6 HU, p < 0.001), whereas MRI demonstrated increased signal intensities in pathological regions. ROC analysis indicated comparable diagnostic performance for DECT (AUC = 0.84) and MRI (AUC = 0.80). A strong inverse correlation (r = -0.83) was observed between DECT-measured collagen densities and MRI signal intensities. Clinical improvements at follow-up were reflected by normalization trends in both imaging modalities, though not statistically significant.

CONCLUSIONS

Collagen-sensitive DECT provides a reliable quantitative approach for detecting and assessing tendon pathologies in load-induced tendinopathy, demonstrating diagnostic capabilities comparable to MRI while offering the possibility for collagen density quantification.

Для цитирования: Diekhoff Torsten, Kim Suchung, Gwinner Clemens, Winkler Tobias, Stoeckle Ulrich, Perka Carsten, Halfter Finn, Mews Jürgen, Hamm Bernd, Lerchbaumer Markus Herbert. Collagen-sensitive dual-energy-CT as a quantitative tool for tendinopathy assessment: a prospective diagnostic accuracy study.. Skeletal radiology. 2026. DOI: 10.1007/s00256-026-05199-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.