OBJECTIVES

Nucleic acid amplification tests (NAATs) are highly sensitive for the detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) DNA/ribosomal RNA (rRNA). Previous studies have demonstrated contamination of surfaces in sexual health clinics (SHCs) with CT/NG. False positive results can occur if patient samples are contaminated by environmental DNA/rRNA. This can have a dramatic impact on patients' lives and relationships. Previous attempts to reduce contamination, through staff training alone, have been unsuccessful. We aimed to investigate environmental contamination levels in SHCs and to assess a two-armed intervention aimed at reducing surface contamination.

METHODS

Questionnaires were sent to 10 SHCs. Six clinics, with differing characteristics, were selected to participate in sample collection. Each clinic followed standardised instructions to sample surfaces using a CT/NG NAAT swab. Clinics were invited to introduce the two-armed intervention. The first arm was cleaning with a chlorine-based cleaning solution once daily. The second arm involved introducing clinic-specific changes to reduce contamination.

RESULTS

7/10 (70%) clinics completed the questionnaire. Overall, 88/263 (33%) swabs were positive for CT/NG. Clinics 1, 3 and 4 had high levels of contamination, with 28/64 (44%), 17/33 (52%) and 30/52 (58%) swabs testing positive, respectively. Clinics 2 and 6 had lower levels of contamination, with 7/46 (15%) and 6/35 (17%), respectively. 0/33 (0%) of swabs were positive at clinic 5 and this was the only clinic already using a chlorine-based solution to clean all surfaces and delivering twice-yearly clinic-specific infection control training. Following both intervention arms at clinic 1, 2/50 (4%, p<0.0001) swabs tested positive for CT/NG. Clinic 4 introduced each arm separately. After the first intervention, 13/52 (25%, p=0.003) swabs tested positive and following the second arm 4/50 (8%, p<0.0001) swabs were positive.

CONCLUSIONS

Environmental contamination is a concern in SHCs. We recommend that all SHCs monitor contamination levels and, if necessary, consider using chlorine-based cleaning products and introduce clinic-specific changes to address environmental contamination.

Для цитирования: Ramsden Sophie, Ovens Katie, Griffiths James, Muir Peter, Steele-Nicholson Ann, Horner Paddy J. Environmental contamination by Chlamydia trachomatis and Neisseria gonorrhoeae: is it time to change our infection control practices? Results of a regional study.. Sexually transmitted infections. 2022. DOI: 10.1136/sextrans-2021-055360.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.