Real-time use of a computer-aided system for polyp detection during colonoscopy, an ambispective study.
Аннотация
OBJECTIVE
This study aimed to evaluate ambispectively the effectiveness of a real-time computer-aided detection (CADe) system on the number of polyp (PPC) or adenoma per colonoscopy (APC), and polyp (PDR) or adenoma detection rate (ADR).
METHODS
Eight-five videos marked using the CADe system, together with the unmarked videos, were reviewed by two senior endoscopists. Polyps detected in the marked and unmarked videos were recounted in parallel. Additionally, 128 consecutive patients were enrolled for a prospective evaluation using a standard colonoscopy or the CADe monitor alternately every 2 weeks. The PC, APC, PDR and ADR were compared between the two groups.
RESULTS
The total number of polyps reported in the unmarked and marked videos were 73 and 88, respectively (mean PPC 0.86 vs 1.04, P = 0.001). The proportion of polyps detected per colonoscopy increased by 20.5%. Of the 128 prospectively enrolled patients, 186 polyps were detected. The mean PPC was higher in the CADe colonoscopy than in the standard colonoscopy (1.66 vs 1.13, P = 0.039). The PDR using the CADe colonoscopy was significantly higher than that of the standard colonoscopy (78.1% vs 56.3%, P = 0.008).
CONCLUSION
Real-time CADe system significantly increases the PDR and PPC under the situation of a high rate of polyp detection.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.