MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0029-7844(98)00249-x

Медицинская библиотека · Obstetrics and gynecology · 1998

Intrapartum amniotic fluid index: a poor predictor of abnormal fetal size.

Hendrix N W, Chauhan S P, Magann E F, Martin J N, Morrison J C, Devoe L D

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Using receiver-operating characteristic (ROC) curves, we tried to determine the diagnostic threshold of amniotic fluid index (AFI) that will identify abnormal fetal size (birth weights under 2500 g or at least 4000 g) at 37 weeks or beyond.

METHODS

We analyzed prospectively over 2 years all parturients with intact membranes and known AFI in early labor. Patients with the following conditions were excluded: pregestational or gestational diabetes, known anomalies, and preterm labor. Two ROC curves were constructed, and the areas (+/- standard error of the mean [SE]) under the curves were calculated. P < .05 was considered significant.

RESULTS

Of the 1038 subjects meeting study criteria, 3.6% and 11.5% gave birth to infants who were small for gestational age (SGA) or macrosomic, respectively. Overall, 28.7% had oligohydramnios (AFI at most 5.0 cm) and 3.6% had hydramnios (AFI at least 24.0 cm). Small for gestational age was more common in patients with AFI at most 5.0 cm (6.4%) than in those with adequate fluid (AFI 5.1-23.9; 2.5%), or hydramnios (2.7%; P = .012). Macrosomic newborns were less likely to be born to women with oligohydramnios (7.7%) than to those with adequate amniotic fluid (13.1%) or hydramnios (13.5%). Areas under ROC curves are not significantly different from the area under the nondiagnostic line, indicating that AFI (0-34 cm) cannot differentiate between newborns under 2500 g and at or over 2500 g or under 4000 and at or more 4000 g.

CONCLUSION

Intraparterium AFI appears to be a poor screening test to identify risk for delivery of SGA or macrosomic fetus.

Для цитирования: Hendrix N W, Chauhan S P, Magann E F, Martin J N, Morrison J C, Devoe L D. Intrapartum amniotic fluid index: a poor predictor of abnormal fetal size.. Obstetrics and gynecology. 1998. DOI: 10.1016/s0029-7844(98)00249-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.