Treatment Effects of Short-Term Continuous Positive Airway Pressure on Blood Glucose Control in Type 2 Diabetic Patients with Obstructive Sleep Apnea Syndrome.

Wei Cui Ying, He Zhong Ming, Yan Han, Li Jing, An Pei, Zhao Long, Ji Li Nong, Gao Zhan Cheng, Dong Xiao Song, Han Fang

СтатьяПеревод в очереди

Аннотация

PURPOSE: The study aimed at assessing glucose control measured with a continuous glucose monitoring system (CGMS) before and after short-term continuous positive airway pressure (CPAP).

MATERIALS AND

METHODS

Twenty-four type 2 diabetic patients (T2DM) with Obstructive sleep apnea syndrome (OSAS) (mean age 55.0 ± 9.0 years; BMI 29.5 ± 5.2 kg/m2) were admitted and kept under diet control for 2 days, then underwent 2 overnight polysomnographies: a diagnostic study and one with CPAP titration. Then they were treated by CPAP during sleep for the following three nights. Participants were divided into subgroup D (only diet control) and subgroup M (with DM medication). CGMS was utilized over the last five days. Glucose control was also assessed with plasma insulin and a clinical measure of insulin resistance (HOMA-IR) index.

RESULTS

The mean (±SD) apnea-hypopnea index (AHI) at diagnostic polysomnography was 51.2 ± 22.4 (range 10-88) events/h. CPAP treatment in the subjects with OSAS resulted in the index of oxygenation desaturations being reduced from 33.3 ± 20.1 to 1.1 ± 1.6 (P =0.00). CGMS showed mean 24-hours glucose values significantly lower after CPAP treatment than at baseline in both subgroups (7.97±1.31 vs 7.52±0.94, P=0.033 in subgroup D; and 7.72±1.51 vs 7.17±1.21, P=0.05 in subgroup M), as the fasting plasma insulin levels and HOMA-IR were also decreased significantly after CPAP treatment (13.0 ± 7.5μU/mL vs 10.8 ± 5.4μU/mL, P=0.044; and 4.2 ± 2.2 vs 3.1±1.7, P=0.003, respectively). Standard deviation (SD) and mean amplitude of glucose excursions (MAGE) were also decreased in the subgroup D (1.91 ± 1.10 vs 1.61 ± 1.20, P=0.014; 1.26 ± 1.13 vs 1.01 ± 0.98, P=0.008, respectively) only.

CONCLUSION

Short-term CPAP treatment in OSAS with type 2 diabetic patients is accompanied by a decrease in blood glucose level and improved insulin sensitivity. Glucose variability was reduced but only in the patients with diet control.

Для цитирования: Wei Cui Ying, He Zhong Ming, Yan Han, Li Jing, An Pei, Zhao Long, Ji Li Nong, Gao Zhan Cheng, Dong Xiao Song, Han Fang. Treatment Effects of Short-Term Continuous Positive Airway Pressure on Blood Glucose Control in Type 2 Diabetic Patients with Obstructive Sleep Apnea Syndrome.. International journal of general medicine. 2020. DOI: 10.2147/ijgm.s280837.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.