Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2022
A quantitative assay for detection of SARS-CoV-2 neutralizing antibodies.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Cerutti Helena, Bandini Tommaso, Castria Marinunzia, Cartocci Alessandra, Ricci Veronica, Tornesi Stefania, Bogi Alessia, Tesi Giulia, Soldatini Claudia, Toppi Simona, Brogi Alessandra
Аннотация
OBJECTIVES: Serological assays for SARS-CoV-2 have a critical role not only in diagnosis of COVID-19, but also in assessing the degree and duration of response of specific antibodies against the virus obtained through infection or vaccination. We present the results obtained with a competitive immunoenzymatic method (Chorus SARS-CoV-2 "Neutralizing" Ab) for quantitative determination of total neutralizing anti-S1 SARS-CoV-2 antibodies (IgG, IgM, and IgA) in human serum obtained on a disposable device with the Chorus TRIO instrument using a recombinant strong neutralizing antibody as tracer.
METHODS: A total of 694 sera were evaluated for SARS-CoV-2 neutralizing antibodies: 407 uninfected, 201 symptomatic subjects, 37 post-infection patients, and 49 vaccinated. Sixty-eight of the previous sera were used to compare the Chorus SARS-CoV-2 "Neutralizing" Ab results with those obtained with micro-neutralization of the Alpha and original variants. A set of 74 positive sera for other respiratory infections were analyzed to evaluate the possible cross reaction to SARS-CoV-2 virus.
RESULTS: Of the 694 samples, only 3 had discordant results between micro-neutralization and values measured by Chorus SARS-CoV-2 "Neutralizing" Ab: 1 false negative and 2 false positives. Values of sensitivity and specificity were very high: percent positive agreement (sensitivity) 99.6% (95% CI: 97.7 - 99.9) and percent negative agreement (specificity) 99.6% (95% CI: 98.0 -99.9). Concordance was high with a Gwet's Ac1 of 0.992. No significant differences were observed between the alpha and original variants.
CONCLUSIONS: The Chorus SARS-CoV-2 "Neutralizing" Ab test was highly sensitive and specific, and varies from most other currently available tests since it analyzes only antibodies with viral-neutralizing capacity.
METHODS: A total of 694 sera were evaluated for SARS-CoV-2 neutralizing antibodies: 407 uninfected, 201 symptomatic subjects, 37 post-infection patients, and 49 vaccinated. Sixty-eight of the previous sera were used to compare the Chorus SARS-CoV-2 "Neutralizing" Ab results with those obtained with micro-neutralization of the Alpha and original variants. A set of 74 positive sera for other respiratory infections were analyzed to evaluate the possible cross reaction to SARS-CoV-2 virus.
RESULTS: Of the 694 samples, only 3 had discordant results between micro-neutralization and values measured by Chorus SARS-CoV-2 "Neutralizing" Ab: 1 false negative and 2 false positives. Values of sensitivity and specificity were very high: percent positive agreement (sensitivity) 99.6% (95% CI: 97.7 - 99.9) and percent negative agreement (specificity) 99.6% (95% CI: 98.0 -99.9). Concordance was high with a Gwet's Ac1 of 0.992. No significant differences were observed between the alpha and original variants.
CONCLUSIONS: The Chorus SARS-CoV-2 "Neutralizing" Ab test was highly sensitive and specific, and varies from most other currently available tests since it analyzes only antibodies with viral-neutralizing capacity.