MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s1047951121002948

Медицинская библиотека · Cardiology in the young · 2021

Impact of atrial septal defect device size on biventricular global and regional function: a two-dimensional strain echocardiographic study.

Alkhateeb Areej, Roushdy Alaa, Hasan-Ali Hosam, Kishk Yehia T, El Sayegh Aya, Hassan Ayman K M

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

In this study, we assessed the acute changes in biventricular longitudinal strain after atrial septal defect transcatheter closure and its relation to the device size.

METHODS

Hundred atrial septal defect patients and 40 age-matched controls were included. Echocardiography and strain study were performed at baseline and 24 hours and 1 month after the intervention. The study group was divided into two subgroups; group 1: smaller devices were used (mean device size = 1.61 ± 0.05 cm, n = 74) and group 2: larger devices were used (mean device size = 2.95 ± 0.07 cm, n = 26).

RESULTS

At baseline, there was a significant difference between the study group and controls as regards right ventricular global longitudinal strain with significant hyperkinetic apex (p = 0.033, p = 0.020, respectively). There was a significant immediate reduction in right ventricular global longitudinal strain (from -24.43 ± 0.49% to -21.62 ± 0.47%, p < 0.001), which showed insignificant improvement after 1-month follow-up. While only left ventricular global longitudinal strain increased after 1 month. Within 24 hours of device closure, all the basal- and mid-lateral segments strains and apical right ventricular strains showed a significant reduction. There was a significant negative correlation between the indexed large device size and an immediate change in the right ventricular global longitudinal strain (r = -0.425, p = 0.034).

CONCLUSION

Significant right ventricular global longitudinal strain reduction starts as early as 24 hours after transcatheter closure, irrespective of the device size used. The rapid impact of closure was mainly on the biventricular basal and lateral segments and right ventricular apical ones, especially with the large sized atrial septal defect.

Для цитирования: Alkhateeb Areej, Roushdy Alaa, Hasan-Ali Hosam, Kishk Yehia T, El Sayegh Aya, Hassan Ayman K M. Impact of atrial septal defect device size on biventricular global and regional function: a two-dimensional strain echocardiographic study.. Cardiology in the young. 2021. DOI: 10.1017/s1047951121002948.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.