MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0300-8932(03)76917-6

Медицинская библиотека · Revista espanola de cardiologia · 2003

[Detection of angiographic lesions in the left anterior descending coronary artery by transthoracic Doppler echocardiography: usefulness of non-invasive assessment of coronary flow reserve].

Florenciano Sánchez Rafael, La Morena Valenzuela Gd Gonzalo de, Soria Arcos Federico, Rubio Patón Ramón, López Palop Ramón, Villegas García Manuel, Pinar Bermúdez Eduardo, Valdés Chávarri Mariano

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

We evaluated the feasibility of detecting blood flow in the left anterior descending coronary artery and the usefulness of measuring coronary flow reserve to diagnose significant coronary artery disease, both by means of transthoracic Doppler echocardiography using a high-frequency transducer and echo-contrast agent.

PATIENTS AND METHOD: We studied 107 patients who were scheduled for coronary arteriography for known or suspected ischemic heart disease. A Doppler signal was recorded by a pulsed wave in the distal left anterior descending artery at baseline and after dipyridamole infusion. An echo-contrast agent was administered to all patients. A coronary flow reserve equal to or higher than 1.7 was considered normal.

RESULTS

We recorded Doppler signals in the left anterior descending coronary artery of 83 patients (78%). Significant stenosis of the left anterior descending coronary artery was observed in 24 out of 83 patients (29%). The prevalence of significant stenosis was higher (62 vs 29%; p = 0.006) in patients in which no Doppler signal was detected. The sensitivity, specificity, and accuracy of abnormal coronary flow reserve in detecting significant stenosis of the left anterior descending coronary artery were 87, 74 and 78%, respectively.

CONCLUSIONS

The measurement of coronary flow reserve by transthoracic Doppler echocardiography using a high-frequency transducer and echo-contrast agent is a feasible, widely available, and accurate method for detecting significant stenosis of the left anterior descending coronary artery.

Для цитирования: Florenciano Sánchez Rafael, La Morena Valenzuela Gd Gonzalo de, Soria Arcos Federico, Rubio Patón Ramón, López Palop Ramón, Villegas García Manuel, Pinar Bermúdez Eduardo, Valdés Chávarri Mariano. [Detection of angiographic lesions in the left anterior descending coronary artery by transthoracic Doppler echocardiography: usefulness of non-invasive assessment of coronary flow reserve].. Revista espanola de cardiologia. 2003. DOI: 10.1016/s0300-8932(03)76917-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.