MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/jaha.114.001209

Медицинская библиотека · Journal of the American Heart Association · 2014

Factors associated with periesophageal vagal nerve injury after pulmonary vein antrum isolation.

Miyazaki Shinsuke, Taniguchi Hiroshi, Kusa Shigeki, Komatsu Yuki, Ichihara Noboru, Takagi Takamitsu, Iwasawa Jin, Kuroi Akio, Nakamura Hiroaki, Hachiya Hitoshi, Hirao Kenzo, Iesaka Yoshito

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Periesophageal vagal nerve injury is recognized as a rare complication in atrial fibrillation ablation procedures. We investigated the factors associated with the occurrence of symptomatic periesophageal vagal nerve injury after pulmonary vein antrum isolation.

METHODS AND

RESULTS

Overall, 535 consecutive patients who underwent sole pulmonary vein antrum isolation were included. Point-by-point radiofrequency applications were applied using irrigated-tip catheters under minimal sedation without esophageal temperature monitoring. In the initial 165 patients, the ablation settings for the posterior left atrium were a maximum energy of 25 to 30 W and a duration of 30 seconds. In the subsequent 370 patients, the power was additionally limited to 20 to 25 W at specific parts of the posterior left atrium where the ablation line transversed the esophagus. Symptomatic gastric hypomotility was found in 13 patients, and all were observed during the initial period (7.9%). No other collateral damage was observed. Logistic regression analysis revealed that the body mass index was the only independent predictor for identifying patients with gastric hypomotility (odds ratio 0.770; 95% confidence interval 0.643 to 0.922; P=0.0045) during the initial period. The prevalence of gastric hypomotility was significantly higher in the initial study period than subsequently (0 of 370, 0%; P<0.0001). All except for 1 patient recovered completely with conservative treatment within 4 months after the procedure.

CONCLUSIONS

Periesophageal vagal nerve injury is more common collateral damage than direct esophageal injury in pulmonary vein antrum isolation procedures. Titrating the radiofrequency energy at specific areas where the ablation line transverses the esophagus and taking account of the body mass index might reduce occurrences not only of direct esophageal damage but also of periesophageal vagal nerve injury in pulmonary vein antrum isolation procedures.

Для цитирования: Miyazaki Shinsuke, Taniguchi Hiroshi, Kusa Shigeki, Komatsu Yuki, Ichihara Noboru, Takagi Takamitsu, Iwasawa Jin, Kuroi Akio, Nakamura Hiroaki, Hachiya Hitoshi, Hirao Kenzo, Iesaka Yoshito. Factors associated with periesophageal vagal nerve injury after pulmonary vein antrum isolation.. Journal of the American Heart Association. 2014. DOI: 10.1161/jaha.114.001209.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.