MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/00206097509071724

Медицинская библиотека · Audiology : official organ of the International Society of Audiology · 1975

Stapedius reflex abnormalities in multiple sclerosis.

Colletti V

СтатьяПеревод в очереди

Аннотация

Thirteen patients suffering from multiple sclerosis were analyzed by a Madsen ZO 70 electroacoustic bridge connected to an electronystagmograph through an impedance adaptor. Threshold, amplitude, decay and difference limen of intensity (DLI) of the stapedius reflex were examined for the frequencies 500, 1 000, 2 000 and 4 000 Hz. The difference between standard audiometric results and stapedius reflex data stresses the value of reflex measurements in assessing brain stem pathology.

Для цитирования: Colletti V. Stapedius reflex abnormalities in multiple sclerosis.. Audiology : official organ of the International Society of Audiology. 1975. DOI: 10.3109/00206097509071724.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.