OBJECTIVE

Deep sedation of mechanically ventilated patients is associated with poorer outcomes, including longer hospital length of stay and more ventilator days. In contrast, light sedation is associated with decreased hospital and intensive care unit length of stay, lower ventilator days, and decreased mortality. This study sought to decrease the use of unindicated deep sedation and benzodiazepine use in mechanically ventilated patients during critical care transport. Previous work identified > 90% of intubated, nonparalyzed patients were deeply sedated in this critical care transport system.

METHODS

This study was conducted at a critical care transport service affiliated with a rural academic medical center. Chart review of all mechanically ventilated adults transported between January and November 2023 with no indication for deep sedation was performed. Improvement initiatives were implemented using Plan-Do-Study-Act cycles and included transport crew education, guideline revision, and enhanced performance feedback.

RESULTS

A 25% reduction in the proportion of deeply sedated patients was achieved.

CONCLUSION

Deep sedation is not universally indicated in critical care transport of mechanically ventilated patients. This quality improvement initiative achieved its main aim of reducing the proportion of deeply sedated patients by 25% with the implementation of 3 Plan-Do-Study-Act cycles.

Для цитирования: Anton Matthew E, Altomare Antonia L, Blais Amanda R, Patten Jeremy C, Fjeld Kalle J, Esteves Alyson M, Roginski Matthew A. Reducing Deep Sedation and Benzodiazepine Use in Mechanically Ventilated Patients During Critical Care Transport: A Quality Improvement Initiative.. Air medical journal. 2024. DOI: 10.1016/j.amj.2024.08.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.