DOI 10.1148/radiology.167.2.3282263
Duodenal perforation as a delayed complication of placement of a biliary endoprosthesis.
Аннотация
Duodenal perforation may occur at the time of insertion of a biliary endoprosthesis or following endoscopic manipulation of such a stent. The possibility of perforation as a late sequela of stent migration, after percutaneous placement of an endoprosthesis, however, has not been emphasized. In the authors' experience with a 12-F soft-stent endoprosthesis, duodenal perforation occurred in four of 50 patients following initially satisfactory stent placement. One intraperitoneal perforation necessitated immediate surgical intervention. The three retroperitoneal perforations were treated conservatively.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.