DOI 10.1097/md.0000000000027165
A meta-analysis of the association of atrial septal abnormalities and atrial vulnerability.
Аннотация
BACKGROUND
The mechanism of cryptogenic stroke (CS) in patients with atrial septal abnormalities remains unclear, and the increased incidence of atrial vulnerability may be one of the reasons. We performed this meta-analysis to clarify the association between atrial septal abnormalities and atrial vulnerability, and to provide evidence-based basis for the prevention and mechanism of CS.
METHODS
We systematically searched for studies on the association between atrial septal abnormalities and atrial vulnerability, and pooled available data on types of atrial septal abnormalities, types of atrial vulnerability, and methods of atrial vulnerability detection. The primary endpoints were the occurrence of atrial arrhythmias or P wave abnormalities. Random-effects models were used to calculate odds ratios (OR) and 95% confidence intervals (CI).
RESULTS
Twelve case-control studies were eligible. Compared with the control group, patients with atrial septal abnormalities had a higher risk of atrial vulnerability (OR: 1.93; 95% CI: 1.13-3.30, P = .02). Data based on stroke patients showed that the group with atrial septal abnormalities had a higher risk of atrial vulnerability than the control group (OR: 2.00; 95% CI: 1.13-3.53, P = .02). However, there was no significant difference in the incidence of atrial vulnerability between the 2 groups of nonstroke patients. Subgroup analysis showed that although atrial septal abnormality increased the risk of atrial vulnerability in the subgroup of atrial septal aneurysm (OR: 1.68; 95% CI: 0.47-5.95, P = .42), the subgroup of atrial fibrillation (AF)/atrial fluster (OR: 1.81; 95% CI: 0.94-3.46, P = .07) and the subgroup of subcutaneous recording system (OR: 1.33; 95% CI: 0.68-2.61, P = .41), the difference was not statistically significant.
CONCLUSIONS
Atrial septal abnormalities can increase the risk of atrial vulnerability, and atrial arrhythmia caused by atrial septal abnormalities may be one of the mechanisms of CS.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.