Evaluating cognitive biases in AI-assisted mammography interpretation: a simulation reader study of explainable AI across radiologist experience levels.

Pesapane Filippo, Latronico Antuono, Abbate Francesca, Penco Silvia, Rotili Anna, Dominelli Valeria, Nicosia Luca, Monzani Dario, Grasso Roberto, Pravettoni Gabriella, Cassano Enrico

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the impact of automation and anchoring bias in artificial intelligence (AI)-assisted mammography interpretation and to assess whether saliency-based explainable AI (XAI) mitigates these biases across radiologists of varying experience.

MATERIALS AND

METHODS

In this monocentric, fully crossed simulation reader study conducted between March and June 2024, six breast radiologists stratified by experience independently reviewed 200 mammograms under three sequential conditions: unassisted, AI-assisted, and AI-assisted with saliency-based XAI heatmaps. To quantify susceptibility to misleading AI advice under controlled discordance conditions, BI-RADS-like AI recommendations were deliberately perturbed by one category in 30% of examinations, whereas the remaining 70% retained the native AI output. Bias outcomes were analyzed using generalized linear mixed-effects models accounting for reader- and case-level clustering.

RESULTS

In the AI-assisted condition without explanations, automation bias occurred in 65/180 (36.1%) and anchoring bias in 61/180 (33.9%) of manipulated cases. With XAI, these rates decreased to 32/180 (17.8%) and 31/180 (17.2%), respectively. In mixed-effects models, XAI was associated with lower odds of automation bias (aOR 0.56, 95% CI 0.44-0.71; p < 0.001) and anchoring-related revision bias (aOR 0.61, 95% CI 0.48-0.78; p < 0.001). On the non-manipulated subset, diagnostic accuracy improved from 724/840 (86.2%) in the unaided phase to 757/840 (90.1%) in the AI + XAI phase.

CONCLUSION

Automation and anchoring bias affected AI-assisted mammography interpretation, particularly among less experienced radiologists. Saliency-based explainable AI reduced, but did not eliminate, these effects.

KEY POINTS: Question AI assistance can systematically influence BI-RADS decisions in mammography, particularly among less experienced radiologists, through automation and anchoring biases. Findings Saliency-based explainable AI (XAI) substantially reduces biased decisions while modestly improving overall diagnostic accuracy compared with standard AI support alone. Clinical relevance Embedding XAI and targeted training into AI-assisted mammography workflows may enhance patient safety and support safer clinical integration of mammography AI tools.

Для цитирования: Pesapane Filippo, Latronico Antuono, Abbate Francesca, Penco Silvia, Rotili Anna, Dominelli Valeria, Nicosia Luca, Monzani Dario, Grasso Roberto, Pravettoni Gabriella, Cassano Enrico. Evaluating cognitive biases in AI-assisted mammography interpretation: a simulation reader study of explainable AI across radiologist experience levels.. European radiology. 2026. DOI: 10.1007/s00330-026-12666-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.