BACKGROUND

Transcutaneous bilirubin (TcB) meters are widely used for screening newborns for jaundice, with a total serum bilirubin (TSB) measurement indicated when the TcB value is classified as "positive" by using a decision rule. The goal of our study was to assess the clinical utility of 3 recommended TcB screening decision rules.

METHODS

Paired TcB/TSB measurements were collected at 34 newborn nursery sites. At 27 sites (sample 1), newborns were routinely screened with a TcB measurement. For sample 2, sites that typically screen with TSB levels also obtained a TcB measurement for the study. Three decision rules to define a positive TcB measurement were evaluated: ≥75th percentile on the Bhutani nomogram, 70% of the phototherapy level, and within 3 mg/dL of the phototherapy threshold. The primary outcome was a TSB level at/above the phototherapy threshold. The rate of false-negative TcB screens and percentage of blood draws avoided were calculated for each decision rule.

RESULTS

For sample 1, data were analyzed on 911 paired TcB-TSB measurements from a total of 8316 TcB measurements. False-negative rates were <10% with all decision rules; none identified all 31 newborns with a TSB level at/above the phototherapy threshold. The percentage of blood draws avoided ranged from 79.4% to 90.7%. In sample 2, each rule correctly identified all 8 newborns with TSB levels at/above the phototherapy threshold.

CONCLUSIONS

Although all of the decision rules can be used effectively to screen newborns for jaundice, each will "miss" some infants with a TSB level at/above the phototherapy threshold.

Для цитирования: Taylor James A, Burgos Anthony E, Flaherman Valerie, Chung Esther K, Simpson Elizabeth A, Goyal Neera K, Von Kohorn Isabelle, Dhepyasuwan Niramol, BORN Investigators. Utility of Decision Rules for Transcutaneous Bilirubin Measurements.. Pediatrics. 2016. DOI: 10.1542/peds.2015-3032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.