MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2017.06.074

Медицинская библиотека · Journal of chromatography. A · 2017

Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.

Cocovi-Solberg David J, Esteve-Turrillas Francesc A, Armenta Sergio, de la Guardia Miguel, Miró Manuel

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to be dramatically deteriorated with reuse. The method provided a limit of detection of 0.3 and 0.14μgL-1 for cocaine and ecgonine methyl ester, respectively, with relative standard deviation values from 8 till 14% with a total analysis time per sample of 7.5min. Method trueness was evaluated by analyzing oral fluid samples spiked with cocaine at different concentration levels (1, 5 and 25μgL-1) affording relative recoveries within the range of 85±24%. Fifteen saliva samples were collected from volunteers and analysed following the proposed automatic procedure, showing a 40% cocaine occurrence with concentrations ranging from 1.3 to 97μgL-1. Field saliva samples were also analysed by reference methods based on lateral flow immunoassay and gas chromatography-mass spectrometry. The application of this procedure to the control of oral fluids of cocaine consumers represents a step forward towards the development of a point-of-care cocaine abuse sensing system.

Для цитирования: Cocovi-Solberg David J, Esteve-Turrillas Francesc A, Armenta Sergio, de la Guardia Miguel, Miró Manuel. Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.. Journal of chromatography. A. 2017. DOI: 10.1016/j.chroma.2017.06.074.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.