MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1142/s0218810411005205

Медицинская библиотека · Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand · 2011

Reoperation for metalwork complications following the use of volar locking plates for distal radius fractures: a United Kingdom experience.

Sahu A, Charalambous C P, Mills S P, Batra S, Ravenscroft M J

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

Volar locking plates are increasingly used in the management of distal radius fractures. As with any new implant, understanding the rate and type of potential metalwork related complications is important. In this study, we reviewed 114 distal radius fractures treated with volar locking plating. Our aim was to determine the type and rate of metalwork complications requiring reoperation. In our series, 12 cases (10%) underwent further surgery for metalwork related complications mainly for screw protrusion into the radiocarpal joint following fracture collapse. Our results suggest that volar locking plates are associated with a high rate of metal work related complications requiring further surgery. Technical aspects to reduce such complications are discussed.

Для цитирования: Sahu A, Charalambous C P, Mills S P, Batra S, Ravenscroft M J. Reoperation for metalwork complications following the use of volar locking plates for distal radius fractures: a United Kingdom experience.. Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand. 2011. DOI: 10.1142/s0218810411005205.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.