Zhuang Bing, Gan Liangying, Liu Bin, Yuan Weijie, Shi Ming, Peng Ai, Wang Lihua, Chen Xiaolan, Liu Tongqiang, Zhang Shiying, Wang Song, Gao Qing, Wang Baoxing, Zheng Huixiao, Liu Changhua, Luo Yuan, Ye Hong, Lin Hongli, Li Yiwen, He Qiang, Zheng Feng, Luo Ping, Long Gang, Lu Wei, Li Kanghui, Yang Junwei, Liu Yingxue Cathy, Zhang Zhizheng, Li Xiaoling, Zhang Weifeng, Zuo Li

СтатьяКлиническое исследование II фазыРандомизированное исследованиеМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

VS-505 (AP301), an acacia and ferric oxyhydroxide polymer, is a novel fiber-iron-based phosphate binder. This two-part Phase 2 study evaluated the tolerability, safety and efficacy of oral VS-505 administered three times daily with meals in treating hyperphosphatemia in chronic kidney disease (CKD) patients receiving maintenance hemodialysis (MHD).

METHODS

In Part 1, patients received dose-escalated treatment with VS-505 2.25, 4.50 and 9.00 g/day for 2 weeks each, guided by serum phosphorus levels. In Part 2, patients received randomized, open-label, fixed-dosage treatment with VS-505 (1.50, 2.25, 4.50 or 6.75 g/day) or sevelamer carbonate 4.80 g/day for 6 weeks. The primary efficacy endpoint was the change in serum phosphorus.

RESULTS

The study enrolled 158 patients (Part 1: 25; Part 2: 133), with 130 exposed to VS-505 in total. VS-505 was well tolerated. The most common adverse events were gastrointestinal disorders, mainly feces discolored (56%) and diarrhea (15%; generally during Weeks 1-2 of treatment). Most gastrointestinal disorders resolved without intervention, and none was serious. In Part 1, serum phosphorus significantly improved (mean change -2.0 mg/dL; 95% confidence interval -2.7, -1.4) after VS-505 dose escalation. In Part 2, serum phosphorus significantly and dose-dependently improved in all VS-505 arms, with clinically meaningful reductions with VS-505 4.50 and 6.75 g/day, and sevelamer carbonate 4.80 g/day [mean change -1.6 (-2.2, -1.0), -1.8 (-2.4, -1.2) and -1.4 (-2.2, -0.5) mg/dL, respectively]. In both parts, serum phosphorus reductions occurred within 1 week of VS-505 initiation, returning to baseline within 2 weeks of VS-505 discontinuation.

CONCLUSION

VS-505, a novel phosphate binder, was well tolerated with a manageable safety profile, and effectively and dose-dependently reduced serum phosphorus in CKD patients with hyperphosphatemia receiving MHD.

CLINICAL TRIAL REGISTRATION NUMBER: NCT04551300 .

Для цитирования: Zhuang Bing, Gan Liangying, Liu Bin, Yuan Weijie, Shi Ming, Peng Ai, Wang Lihua, Chen Xiaolan, Liu Tongqiang, Zhang Shiying, Wang Song, Gao Qing, Wang Baoxing, Zheng Huixiao, Liu Changhua, Luo Yuan, Ye Hong, Lin Hongli, Li Yiwen, He Qiang, Zheng Feng, Luo Ping, Long Gang, Lu Wei, Li Kanghui, Yang Junwei, Liu Yingxue Cathy, Zhang Zhizheng, Li Xiaoling, Zhang Weifeng, Zuo Li. Tolerability, safety and efficacy of a novel phosphate binder VS-505 (AP301): a Phase 2 dose-escalation and dose-ranging study in patients undergoing maintenance hemodialysis.. Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association. 2024. DOI: 10.1093/ndt/gfae053.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.