m+Medelevator.RU
← Поиск публикаций
Diabetes technology & therapeutics · 2025

A Real-World Study Comparing Advanced Hybrid Closed-Loop Systems During Pregnancy in Women with Type 1 Diabetes.

СтатьяМногоцентровое исследованиеСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Quirós Carmen, Wägner Ana M, Azriel Sharona, Soldevila Berta, Beato-Vibora Pilar I, Herrera Arranz Mayte, Nattero Lía, Picón-César María José, Climent Elisenda, Amigó Judit, Colomo Natalia, Durán-Martínez María, Alpañes Buesa Macarena, Megía Ana, Vinagre Irene, Vega Guedes Begoña, Díaz-Soto Gonzalo, Bandrés Orosia, Barquiel Beatriz, López Tinoco Cristina, Márquez-Pardo Rosa, Martínez-Brocca Maria A, Corcoy Rosa, Codina Mercè, Piedra María, Rebollo Román Ángel, Cuesta Martín, López-Gallardo Gema, Goya Canino Maria M, Bugatto Fernando, Mendoza Lilian C, Olvera Márquez María Del Pilar, Perea Verónica

Аннотация

OBJECTIVE: To compare maternal glucose metrics and pregnancy outcomes of three advanced hybrid closed-loop (aHCL) systems (MiniMed 780G®, CamAPS® FX, and Tandem Control-IQ) in a real-world, multicenter cohort of pregnant women with type 1 diabetes.

RESEARCH DESIGN AND METHODS: Cohort study including 137 pregnant women with type 1 diabetes using aHCL from 27 hospitals in Spain. Participants were grouped according to the aHCL system used: 85 MiniMed 780G (62%), 38 CamAPS FX (27.7%), and 14 Control-IQ (10.2%). Maternal glucose metrics (HbA1c and time spent within [TIRp], below [TBRp], and above [TARp] the pregnancy-specific glucose range 3.5-7.8 mmol/L), as well as pregnancy outcomes, were analyzed. Adjusted models were applied to account for potential confounding factors.

RESULTS: No between-group differences in HbA1c levels were observed at baseline. By the third trimester, CamAPS FX and Control-IQ users had significantly lower HbA1c levels compared with the MiniMed 780G group (βadjusted -4.77 mmol/mol, 95% confidence interval [CI] -7.40 to -2.13; and βadjusted -4.79, 95% CI -8.53 to -1.06; respectively). In the second trimester, CamAPS FX was associated with a higher percentage of time in range (βadjusted +5.88%, 95% CI 1.09 to 10.67) and a lower percentage of time above range (βadjusted -6.36%, 95% CI -11.46 to -1.26) compared with MiniMed 780G, with no other significant differences observed in other trimesters. Both CamAPS FX and Control-IQ were associated with lower odds of large-for-gestational-age (LGA) infants (CamAPS FX: ORadjusted 0.25, 95% CI 0.08 to 0.77; Control-IQ: ORadjusted 0.10, 95% CI 0.01 to 0.99) compared with MiniMed 780G.

CONCLUSIONS: In this multicenter observational study, CamAPS FX and Control-IQ users achieved better glycemic metrics and lower odds of delivering LGA infants compared with those using MiniMed 780G. These findings warrant investigation to confirm associations and inform individualized clinical decision-making in pregnant women with type 1 diabetes.

Предметные рубрики MeSH