A Single-center Experience Comparing First- Versus Second-generation Insertable Cardiac Monitors in Pediatric Patients.
Аннотация
Insertable cardiac monitors (ICMs) have undergone advancements in size and functionality over the past decade, resulting in the introduction of small, easily insertable devices capable of long-term remote monitoring. We define first-generation ICMs as implantable cardiac monitoring devices that require an incision and surgical creation of a subcutaneous pocket and second-generation ICMs as devices implanted using a custom-made tool for subcutaneous insertion, respectively. The aim of this study was to understand the differences between first- and second-generation pediatric ICM implants, implant indications, and time to diagnosis. We performed a retrospective, single-center chart review of patients who underwent ICM implantation from 2009-2019, spanning a 5-year course of first-generation ICM implantations and 5-year course of second-generation ICM implantations. Demographic data, past medical history, implant indication, and time to diagnosis were obtained. A total of 208 patients were identified over the 10-year time period, including 38 (18%) who underwent implantation with a first-generation device and 170 (82%) who underwent implantation with a second-generation device. Implant indications for first-generation ICMs included syncope (71%), palpitations (16%), inherited arrhythmia syndrome (IAS) management (5%), and premature ventricular contractions/ventricular tachycardia (VT) (8%); implant indications for second-generation ICMs included syncope (48%), palpitations (19%), IAS management (40%), premature ventricular contractions/VT (11%), atrial fibrillation (2%), tachycardia (3%), and heart block (0.5%). The average time to diagnosis was 38 weeks for patients with first-generation devices and 55 weeks for those with second-generation devices. With innovations in ICM technologies, there are expanding indications for ICM implantation in pediatric patients for long-term monitoring, specifically regarding the management of IAS patients.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.