MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/(sici)1097-0304(199707)41:3<232::aid-ccd2>3.0.co;2-7

Медицинская библиотека · Catheterization and cardiovascular diagnosis · 1997

Local delivery of c-myb antisense oligonucleotides during balloon angioplasty.

Azrin M A, Mitchel J F, Bow L M, Pedersen C A, Cartun R W, Aretz T H, Waters D D, McKay R G

СтатьяПеревод в очереди

Аннотация

Intraluminal delivery of antisense oligonucleotides to c-myb was assessed following balloon angioplasty in swine peripheral arteries. Successful delivery and intramural persistence of oligonucleotide for over 24 h were demonstrated following angioplasty with hydrogel balloons coated with 32P-labeled antisense. Delivery of fluorescein-labeled antisense demonstrated further localization within the arterial media and intracellularly. Preliminary in vitro studies demonstrated the feasibility of inhibition of porcine lymphocyte proliferation using the murine antisense to c-myb. Twelve iliac or carotid arteries underwent angioplasty with antisense-coated balloons, while the contralateral vessels underwent angioplasty with the same-sized balloons coated with the complementary sense strand. Six to seven days later, dilated arterial segments were surgically isolated. In 10 of 12 vessel pairs, antisense-treated vessels demonstrated less cellular proliferation than did contralateral sense-treated vessels, as assessed by quantitative immunohistochemical staining of proliferating cell nuclear antigen, and smooth muscle cell proliferation was reduced 18% in antisense-treated vessels compared to the contralateral sense-treated vessels (PCNA-positive nuclear area: 7.7 +/- 4.9% vs. 9.3 +/- 5.2%, P < 0.04)-intraluminal delivery of antisense oligonucleotides to c-myb is feasible with a catheter-based system and may reduce smooth muscle cell proliferation following arterial injury.

Для цитирования: Azrin M A, Mitchel J F, Bow L M, Pedersen C A, Cartun R W, Aretz T H, Waters D D, McKay R G. Local delivery of c-myb antisense oligonucleotides during balloon angioplasty.. Catheterization and cardiovascular diagnosis. 1997. DOI: 10.1002/(sici)1097-0304(199707)41:3<232::aid-ccd2>3.0.co;2-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.