MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0735-1097(02)02766-3

Медицинская библиотека · Journal of the American College of Cardiology · 2003

Duration of abnormal SPECT myocardial perfusion imaging following resolution of acute ischemia: an angioplasty model.

Fram Daniel B, Azar Rabih R, Ahlberg Alan W, Gillam Linda D, Mitchel Joseph F, Kiernan Francis J, Hirst Jeffrey A, Mather Jeffrey F, Ficaro Edward, Cyr Gizelle, Waters David, Heller Gary V

Клиническое исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

This study was designed to determine how long nuclear myocardial perfusion imaging (MPI) remains abnormal following transient myocardial ischemia.

BACKGROUND

Acute rest MPI identifies myocardial ischemia with a high sensitivity when the radionuclide is injected during chest pain. However, the sensitivity of this technique is uncertain when the radionuclide is injected following the resolution of symptoms.

METHODS

Forty patients undergoing successful coronary angioplasty were randomized into four equal groups. Tc-99m sestamibi was injected intravenously during the last balloon inflation (acute MPI) in 30 patients and then reinjected 1, 2, or 3 h later (delayed MPI). In a fourth group, the radiopharmaceutical was injected at 15 min following balloon deflation (delayed MPI). A final injection was performed at 24 to 48 h (late MPI) in 37 patients (93%).

RESULTS

A perfusion defect was detected in all 30 acute MPI studies; in 7/10 patients (70%) injected at 15 min; in 11/30 patients (37%) injected at 1, 2, or 3 h; and in 7/37 patients (19%) injected at 24 to 48 h. Perfusion scores were 13.0 +/- 9.2 on acute MPI, 5.1 +/- 2.8 at 15 min (p < 0.001 vs. acute MPI); 2.6 +/- 3.0 at 1, 2, and 3 h (p < 0.001 vs. acute MPI); and 1.3 +/- 2.4 at 24 to 48 h (p < 0.001 vs. acute MPI; p < 0.03 vs. delayed MPI).

CONCLUSIONS

Myocardial perfusion imaging may remain abnormal for several hours following transient myocardial ischemia even when normal flow is restored in the epicardial coronary artery.

Для цитирования: Fram Daniel B, Azar Rabih R, Ahlberg Alan W, Gillam Linda D, Mitchel Joseph F, Kiernan Francis J, Hirst Jeffrey A, Mather Jeffrey F, Ficaro Edward, Cyr Gizelle, Waters David, Heller Gary V. Duration of abnormal SPECT myocardial perfusion imaging following resolution of acute ischemia: an angioplasty model.. Journal of the American College of Cardiology. 2003. DOI: 10.1016/s0735-1097(02)02766-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.