MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000506164

Медицинская библиотека · Neonatology · 2020

Randomized Controlled Trial of Nonsynchronized Nasal Intermittent Positive Pressure Ventilation versus Nasal CPAP after Extubation of VLBW Infants.

Estay Alberto S, Mariani Gonzalo L, Alvarez Claudio A, Milet Beatriz, Agost Daniel, Avila Claudia P, Roldan Liliana, Abdala Daniel A, Keller Rodolfo, Galletti María F, González Alvaro, for the NEOCOSUR Neonatal Network

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Nasal continuous positive airway pressure (NCPAP) is a useful method of respiratory support after extubation. However, some infants fail despite CPAP use and require reintubation. Some evidence suggests that synchronized nasal intermittent positive pressure ventilation (NIPPV) may decrease extubation failure in preterm infants. Nonsynchronized NIPPV (NS-NIPPV) is being widely used in preterm infants without conclusive evidence of its benefits and side effects. Our aim was to evaluate whether NS-NIPPV decreases extubation failure compared with NCPAP in ventilated very low birth weight infants (VLBWI) with respiratory distress syndrome (RDS).

METHODS

Randomized controlled trial of ventilated VLBWI being extubated for the first time. Before extubation, infants were randomized to receive NCPAP or NS-NIPPV. Primary outcome was the need for reintubation within 72 h.

RESULTS

220 infants were included. The mean ± SD birth weight was 1,027 ± 256 g and gestational age 27.8 ± 1.9 weeks. Demographic and clinical characteristics were similar in both groups. Extubation failure was 32.4% for NCPAP versus 32.1% for NS-NIPPV, p = 0.98. The frequency of deaths, bronchopulmonary dysplasia, intraventricular hemorrhage, air leaks, necrotizing enterocolitis and duration of respiratory support did not differ between groups.

CONCLUSIONS

In this population of VLBWI, NS-NIPPV did not decrease extubation failure after RDS compared with NCPAP.

Для цитирования: Estay Alberto S, Mariani Gonzalo L, Alvarez Claudio A, Milet Beatriz, Agost Daniel, Avila Claudia P, Roldan Liliana, Abdala Daniel A, Keller Rodolfo, Galletti María F, González Alvaro, for the NEOCOSUR Neonatal Network. Randomized Controlled Trial of Nonsynchronized Nasal Intermittent Positive Pressure Ventilation versus Nasal CPAP after Extubation of VLBW Infants.. Neonatology. 2020. DOI: 10.1159/000506164.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.