MedElevator Войти в исследования
← Поиск публикаций

DOI 10.12659/ajcr.903433

Медицинская библиотека · The American journal of case reports · 2017

Congenital Chloride Diarrhea (CCD): A Case Report of CCD Suspected by Prenatal Ultrasonography and Magnetic Resonance Imaging (MRI).

Kawamura Takakazu, Nishiguchi Tomizou

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND Congenital chloride diarrhea (CCD) is a rare autosomal recessive disorder that is difficult to distinguish from fetal lower intestinal obstruction. A prenatal diagnosis will make a contribution to the prognosis of the newborn. CASE REPORT We report a rare case of congenital chloride diarrhea (CCD) prenatally suspected by ultrasound and MRI. The prenatal ultrasound revealed signs of intestinal dilatation suggesting lower intestinal obstruction. MRI findings also revealed intestinal dilatation that continued from the rectum. On T1-weighted images, fluid accumulation within the bowel was hypointense. CCD was strongly suspected rather than obstruction of the lower intestinal tract or Hirschsprung's disease. At 37 weeks and 3 days' gestation, cesarean section was performed because of fetal distress. The newborn was a 2396 g male with the Apgar scores 8 (1 min) and 9 (5 min). Watery diarrhea subsequently persisted, and on the 3rd day, hyponatremia and hypochloremia were present. The infant stool was hyperchloremic, so we diagnosed CCD. CONCLUSIONS When ultrasonography reveals signs of fetal gastrointestinal dilatation, lower intestinal obstruction is considered first. CCD is infrequent and has signs of intestinal dilatation similar to those of other intestinal ailments, so distinguishing these conditions is difficult. However, if CCD is suspected early, then use of MRI will allow its diagnosis. If the condition is diagnosed before birth, the prognosis of the newborn will improve.

Для цитирования: Kawamura Takakazu, Nishiguchi Tomizou. Congenital Chloride Diarrhea (CCD): A Case Report of CCD Suspected by Prenatal Ultrasonography and Magnetic Resonance Imaging (MRI).. The American journal of case reports. 2017. DOI: 10.12659/ajcr.903433.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.