Transcatheter closure of secundum atrial septal defects using Amplatzer device.
Аннотация
OBJECTIVE
To evaluate the feasibility and short term results of transcatheter closure of secundum atrial septal defects (TCSASDs) using Amplatzer occluder device. A new self-centering device, the Amplatzer atrial septal occluder, has recently been evaluated in an animal model with excellent results. This paper reports our clinical research with this device.
METHODS
30 patients underwent an attempt at TCSASDs at an average age of 35.6 +/- 15.9 y (range, 5-62 y) and average weight of 63.6 +/- 14.5 kg (range, 17-78 kg) using the Amplatzer atrial septal occluder. The average ASD diameter measured by transesophageal echocardiography (TEE) was 23.6 +/- 4.0 mm (range, 16-31 mm), and the average atrial septal defects (ASD) balloon stretched diameter was 25.2 +/- 5.8 mm (range, 9-34 mm). All patients had right atrial and ventricular volume overload with a Qp/Qs of 3.4 +/- 1.2 (1.4-5.2). A F8-12 catheter was used for delivery of the device in all patients.
RESULTS
The device was placed correctly in all patients. There was immediate and complete closure in 30 patients. The average device waist size used to close the defect was 25.6 +/- 5.9 mm (range, 9-34 mm). There was no episode of device embolization or any other complication. Follow-up was performed using transthoracic echocardiography (TTE) 1 day, 1 month, 3 months, 6 months and 1 year after the procedure. The first day after operation; there was complete closure of the ASD in all patients; there have been no episodes of endocarditis, thromboembolism, or wire fracture.
CONCLUSION
TCSASDs using the Amplatzer occluder device was an efficient nonsurgical method which had a very high technical success rate and satisfactory short term and follow-up results.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.