MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/01.cir.0000039475.66067.dc

Медицинская библиотека · Circulation · 2002

Vasodilator response assessment in porcine myocardium with magnetic resonance relaxometry.

Foltz Warren D, Huang Hong, Fort Stephen, Wright Graham A

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

This research describes an early preclinical study of the biophysical mechanisms governing changes in myocardial T2 during vasodilation in normal myocardium.

METHODS AND

RESULTS

Theoretical modeling and experimental studies in an instrumented pig model (n=7) provided measures of changes in myocardial T2, relative blood volume (BV), and microcirculation oxygen levels (%O2) during intracoronary adenosine infusion. Intracoronary adenosine increases perfusion without increasing blood volume or cardiac metabolic rate; thus, T2 elevations should reflect elevated microcirculation oxygen levels. Robust strategies were used for magnetic resonance imaging (MRI) data collection. Measures of myocardial and vascular T1 before and after Clariscan (Amersham Health) injection provided blood volume assessment. Changes in microcirculation oxygen levels were estimated via direct blood sampling from the left anterior descending (LAD) coronary vein. Perfusion changes were monitored using a Doppler flow wire within the left main coronary artery. Myocardial T2 elevations (DeltaT2=17+/-8%) within the LAD arterial perfusion bed were related to elevations in perfusion (coronary velocity reserve=3.2+/-0.4) and coronary venous %O2 [Delta(LAD CV%O2) =56+/-11%], whereas blood volume (DeltaBV=0 +/-2%) and cardiac metabolic rate [Delta(heart rate x blood pressure) = -4+/-11%] remained constant.

CONCLUSIONS

Myocardial T2 elevation during intracoronary adenosine infusion was significant and repeatable, caused by increases in microcirculation oxygen levels. Changes in microcirculation oxygen levels of approximately 40%O2 should be detectable by this technique. This sensitivity should suffice for differentiating normal from abnormal myocardium via measurement of myocardial perfusion reserve.

Для цитирования: Foltz Warren D, Huang Hong, Fort Stephen, Wright Graham A. Vasodilator response assessment in porcine myocardium with magnetic resonance relaxometry.. Circulation. 2002. DOI: 10.1161/01.cir.0000039475.66067.dc.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.