Diabetes, obesity & metabolism · 2023

Assessment of circulating insulin using liquid chromatography-mass spectrometry during insulin glargine treatment in type 2 diabetes: Implications for estimating insulin sensitivity and β-cell function.

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Seegmiller Jesse C, Schmit David J, Arends Valerie L, Steffes Michael W, Kahn Steven E, Younes Naji, GRADE Research Group

Аннотация

AIM: To determine the potential impact of the cross-reactivity of insulin glargine U-100 and its metabolites on insulin sensitivity and β-cell measures in people with type 2 diabetes.

MATERIALS AND METHODS: Using liquid chromatography-mass spectrometry (LC-MS), we measured concentrations of endogenous insulin, glargine and its two metabolites (M1 and M2) in fasting and oral glucose tolerance test-stimulated plasma from 19 participants and fasting specimens from another 97 participants 12 months after randomization to receive the insulin glargine. The last dose of glargine was administered before 10:00 PM the night before testing. Insulin was also measured on these specimens using an immunoassay. We used fasting specimens to calculate insulin sensitivity (Homeostatic Model Assessment 2 [HOMA2]-S%; QUICKI index; PREDIM index) and β-cell function (HOMA2-B%). Using specimens following glucose ingestion, we calculated insulin sensitivity (Matsuda ISI[comp] index) and β-cell response (insulinogenic index [IGI], and total incremental insulin response [iAUC] insulin/glucose).

RESULTS: In plasma, glargine was metabolized to form the M1 and M2 metabolites that were quantifiable by LC-MS; however, the analogue and its metabolites cross-reacted by less than 100% in the insulin immunoassay. This incomplete cross-reactivity resulted in a systematic bias of fasting-based measures. By contrast, because M1 and M2 did not change following glucose ingestion, a bias was not observed for IGI and iAUC insulin/glucose.

CONCLUSIONS: Despite glargine metabolites being detected in the insulin immunoassay, dynamic insulin responses can be used to assess β-cell responsiveness. However, given the cross-reactivity of the glargine metabolites in the insulin immunoassay, fasting-based measures of insulin sensitivity and β-cell function are biased.