Assessment of Interradiologist Agreement Regarding Mammographic Breast Density Classification Using the Fifth Edition of the BI-RADS Atlas.

Ekpo Ernest U, Ujong Ujong Peter, Mello-Thoms Claudia, McEntee Mark F

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The objective of the present study was to assess interradiologist agreement regarding mammographic breast density assessment performed using the rating scale outlined in the fifth edition of the BI-RADS atlas of the American College of Radiology.

MATERIALS AND

METHODS

Breast density assessments of 1000 cases were conducted by five radiologists from the same institution who together had recently undergone retraining in mammographic breast density classification based on the fifth edition of BI-RADS. The readers assigned breast density grades (A-D) on the basis of the BI-RADS classification scheme. Repeat assessment of 100 cases was performed by all readers 1 month after the initial assessment. A weighted kappa was used to calculate intrareader and interreader agreement.

RESULTS

Intrareader agreement ranged from a kappa value of 0.86 (95% CI, 0.77-0.93) to 0.89 (95% CI, 0.81-0.95) on a four-category scale (categories A-D) and from 0.89 (95% CI, 0.86-0.92) to 0.94 (95% CI, 0.89-0.97) on a two-category scale (category A-B vs category C-D). Interreader agreement ranged from substantial (κ = 0.76; 95% CI, 0.73-0.78) to almost perfect (κ = 0.87; 95% CI, 0.86-0.89) on a four-category scale, and the overall weighted kappa value was substantial (0.79; 95% CI, 0.78-0.83). Interreader agreement on a two-category scale ranged from a kappa value of 0.85 (95% CI, 0.83-0.86) to 0.91 (95% CI, 0.90-0.92), and the overall weighted kappa was 0.88 (95% CI, 0.87-0.89).

CONCLUSION

Overall, with regard to mammographic breast density classification, radiologists had substantial interreader agreement when a four-category scale was used and almost perfect interreader agreement when a dichotomous scale was used.

Для цитирования: Ekpo Ernest U, Ujong Ujong Peter, Mello-Thoms Claudia, McEntee Mark F. Assessment of Interradiologist Agreement Regarding Mammographic Breast Density Classification Using the Fifth Edition of the BI-RADS Atlas.. AJR. American journal of roentgenology. 2016. DOI: 10.2214/ajr.15.15049.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.