MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jemermed.2016.06.031

Медицинская библиотека · The Journal of emergency medicine · 2016

The Inter-rater Reliability of Echocardiographic Diastolic Function Evaluation Among Emergency Physician Sonographers.

Saul Turandot, Avitabile Nicholas C, Berkowitz Rachel, Siadecki Sebastian D, Rose Gabriel, Toomarian Mojdeh, Kaban Nicole L, Governatori Nicholas, Suprun Maria

СтатьяПеревод в очереди

Аннотация

STUDY

OBJECTIVES

In a patient with dyspnea and suspected CHF, the evaluation of diastolic function involves: tissue Doppler of the mitral annulus and 2) pulsed wave Doppler of the mitral inflow. We aimed to 1) determine the inter-rater reliability for overall diastolic function and 2) evaluate the reliability of the individual Doppler measurements.

METHODS

A convenience sample of adult emergency department patients was prospectively enrolled by 8 EPs who had participated in a 1-hour didactic session. Patients were selected if they had a history of CHF or suspected abnormal diastolic function due to chronic hypertension. Diastolic function was considered to be abnormal if Tissue Doppler of the septal e' was <8 cm/s and if the lateral e' was <10 cm/s. In cases of discordance, the E/e' ratio was calculated with ≤8 considered normal and >8 considered abnormal. A Kappa coefficient. Bland-Altman plot and a fixed effect regression model were used in the analysis.

RESULTS

Thirty-two patients were enrolled, and 3 (9.4%) were excluded due to technical inadequacy. The inter-rater reliability among sonographers for overall interpretation was very good: κ = 0.86 (95% CL [0.67, 1.0]). Based on the Bland-Altman plot, was no consistent bias between readers. There was no evidence to conclude that the readings differed among sonographers: septal e' (p = 0.77), lateral e' (p = 0.89) and E (p = 0.15).

CONCLUSION

EP sonographers obtained similar Doppler measurements for diastolic function evaluation with very good inter-rater reliability for the assessment of overall diastolic function.

Для цитирования: Saul Turandot, Avitabile Nicholas C, Berkowitz Rachel, Siadecki Sebastian D, Rose Gabriel, Toomarian Mojdeh, Kaban Nicole L, Governatori Nicholas, Suprun Maria. The Inter-rater Reliability of Echocardiographic Diastolic Function Evaluation Among Emergency Physician Sonographers.. The Journal of emergency medicine. 2016. DOI: 10.1016/j.jemermed.2016.06.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.