Poly Implant Prothèse™ (PIP) experience in the United Kingdom: A prospective cohort study into the accuracy of diagnostic imaging findings in comparison to operative findings of 1029 implants.

Leckenby Jonathan, Chana Jagdeep, Harrison Douglas, Grobbelaar Adriaan

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

The Poly Implant Prosthèse™ (PIP) implants were withdrawn from market use in the United Kingdom on 31st March 2010 following Government issued advice. In June 2012 a final Government report was issued and during this period the majority of patients elected to have their prostheses removed. This study presents the operative findings of three surgeons. 517 patients were identified retrospectively from the implant database as having received PIP implants with a total of 1029 implants. 62 patients (124 implants) declined explantation after consultation and imaging. The data was recorded prospectively for all patients and included the clinical, imaging and operative findings. A total of 905 implants were removed of which 129 were ruptured at the time of explantation (14.25%). 27 implants were intact but the presence of liquid surrounding the prosthesis was noted. 93 implants were reported as being ruptured after diagnostic imaging but were intact operatively resulting in a test sensitivity of 0.82 and a specificity of 0.92 yielding a positive predictive value of 0.59 and a negative predictive value of 0.97 overall. Capsule formation was noted in 27 breasts (3%). Our study showed that the prevalence of PIP ruptures is comparable to other manufacturers. The prevalence of implant rupture predictably increased over time and the prevalence of abnormal capsule formation was similar to other manufacturers.

Для цитирования: Leckenby Jonathan, Chana Jagdeep, Harrison Douglas, Grobbelaar Adriaan. Poly Implant Prothèse™ (PIP) experience in the United Kingdom: A prospective cohort study into the accuracy of diagnostic imaging findings in comparison to operative findings of 1029 implants.. Journal of plastic, reconstructive & aesthetic surgery : JPRAS. 2016. DOI: 10.1016/j.bjps.2016.01.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.