Медицинская библиотека · Annals of surgical oncology · 2013

Computed tomography (CT) venography using a multidetector CT prior to the percutaneous external jugular vein approach for an implantable venous-access port.

Kato Kazuya, Taniguchi Masahiko, Iwasaki Yoshiaki, Sasahara Keita, Nagase Atsushi, Onodera Kazuhiko, Matsuda Minoru, Higuchi Mineko, Kobashi Yuko, Furukawa Hiroyuki

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: The objective of this study was to determine the success rate and complications of using the percutaneous approach of the external jugular vein (EJV) for placement of a totally implantable venous-access port (TIVAP) with a preoperative estimate of the detailed anatomical orientation of the cervical venous plexus using computed tomography venography (CT-V).

METHODS

A prospective cohort study of 45 patients in whom placement of a TIVAP was attempted via the right EJV was conducted. The preoperative anatomical estimation of the cervical venous plexus was performed with CT-V using a Multidetector Helical 16-section CT. The angulation between the right EJV and the right subclavian vein, anterior jugular vein, transverse cervical vein, and suprascapular vein was estimated.

RESULTS

CT-V success was achieved in 45 of 45 patients (100 %). A plexus of veins under the clavicle was most commonly responsible for the insertion of the central venous catheter. The EJV approach resulted in a successful cannulation rate of 93 %. No initial complications of pneumothorax or carotid artery puncture occurred during insertion procedures. Late complications occurred in three patients. These included one port erosion (2 %), one catheter occlusion (2 %), and one wound hematoma (2 %). Catheter-related infections were observed in one patient (2 %).

CONCLUSIONS

The percutaneous EJV approach with CT-V guidance is an optional method for patients with multiple central venous cannulations, those in hemodialysis, or those with long catheter indwelling periods.

Для цитирования: Kato Kazuya, Taniguchi Masahiko, Iwasaki Yoshiaki, Sasahara Keita, Nagase Atsushi, Onodera Kazuhiko, Matsuda Minoru, Higuchi Mineko, Kobashi Yuko, Furukawa Hiroyuki. Computed tomography (CT) venography using a multidetector CT prior to the percutaneous external jugular vein approach for an implantable venous-access port.. Annals of surgical oncology. 2013. DOI: 10.1245/s10434-013-3405-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.