MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fnins.2023.1132173

Медицинская библиотека · Frontiers in neuroscience · 2023

A 1-Tesla MRI system for dedicated brain imaging in the neonatal intensive care unit.

Berson Elisa R, Mozayan Ali, Peterec Steven, Taylor Sarah N, Bamford Nigel S, Ment Laura R, Rowe Erin, Lisse Sean, Ehrlich Lauren, Silva Cicero T, Goodman T Rob, Payabvash Seyedmehdi

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess the feasibility of a point-of-care 1-Tesla MRI for identification of intracranial pathologies within neonatal intensive care units (NICUs).

METHODS

Clinical findings and point-of-care 1-Tesla MRI imaging findings of NICU patients (1/2021 to 6/2022) were evaluated and compared with other imaging modalities when available.

RESULTS

A total of 60 infants had point-of-care 1-Tesla MRI; one scan was incompletely terminated due to motion. The average gestational age at scan time was 38.5 ± 2.3 weeks. Transcranial ultrasound (n = 46), 3-Tesla MRI (n = 3), or both (n = 4) were available for comparison in 53 (88%) infants. The most common indications for point-of-care 1-Tesla MRI were term corrected age scan for extremely preterm neonates (born at greater than 28 weeks gestation age, 42%), intraventricular hemorrhage (IVH) follow-up (33%), and suspected hypoxic injury (18%). The point-of-care 1-Tesla scan could identify ischemic lesions in two infants with suspected hypoxic injury, confirmed by follow-up 3-Tesla MRI. Using 3-Tesla MRI, two lesions were identified that were not visualized on point-of-care 1-Tesla scan: (1) punctate parenchymal injury versus microhemorrhage; and (2) small layering IVH in an incomplete point-of-care 1-Tesla MRI with only DWI/ADC series, but detectable on the follow-up 3-Tesla ADC series. However, point-of-care 1-Tesla MRI could identify parenchymal microhemorrhages, which were not visualized on ultrasound.

CONCLUSION

Although limited by field strength, pulse sequences, and patient weight (4.5 kg)/head circumference (38 cm) restrictions, the Embrace® point-of-care 1-Tesla MRI can identify clinically relevant intracranial pathologies in infants within a NICU setting.

Для цитирования: Berson Elisa R, Mozayan Ali, Peterec Steven, Taylor Sarah N, Bamford Nigel S, Ment Laura R, Rowe Erin, Lisse Sean, Ehrlich Lauren, Silva Cicero T, Goodman T Rob, Payabvash Seyedmehdi. A 1-Tesla MRI system for dedicated brain imaging in the neonatal intensive care unit.. Frontiers in neuroscience. 2023. DOI: 10.3389/fnins.2023.1132173.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.