MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00423-026-04094-3

Медицинская библиотека · Langenbeck's archives of surgery · 2026

A novel real-time assessment of intestinal perfusion with dual imaging using ICG fluorescence and capillaroscopy in colorectal surgery.

Iseki Sadahito, Aoki Takeshi, Watanabe Makoto, Watanabe Ryohei, Kitajima Tetsuya, Oura Keisuke, Miyasaka Shun, Uchida Yusuke, Sekiguchi Koya, Ohira Yasuyuki, Tomioka Kodai, Shibata Hideki, Tashiro Yoshihiko, Nogaki Koji, Date Hiromi, Matsuda Kazuhiro, Yamazaki Kimiyasu, Yamaue Hiroki, Yamochi Toshiko

СтатьяПеревод в очереди

Аннотация

PURPOSE: Anastomotic leakage (AL) is a major complication after colorectal surgery. Indocyanine green fluorescence imaging (ICG-FI) enables real-time assessment of intestinal perfusion, but remains subjective. This study quantitatively evaluated intestinal perfusion by combining ICG-FI with video capillaroscopy (VC).

METHODS

Thirty-two patients undergoing colorectal surgery were enrolled. ICG was administered intravenously before anastomosis. Fluorescence time was defined as the interval from injection to initial fluorescence at the anastomotic site. Microvascular blood-flow velocity was measured intraoperatively using VC in fluorescent and non-fluorescent regions.

RESULTS

AL occurred in 4 of 32 patients (12.5%). The AL group had significantly longer fluorescence time than the non-AL group (32.0 [25.3-34.3] vs. 20.0 [17.3-25.0] s, p = 0.014) and tended to have lower microvascular flow velocity in ICG-fluorescent regions (90.8 [49.0-249.8] vs. 231.7 [164.6-327.3] µm/s, p = 0.064). ROC analysis showed discriminative performance for fluorescence time (AUC 0.88, preliminary cutoff 32 s) and flow velocity (AUC 0.79, preliminary cutoff 101.6 μm/s). Fluorescence time and flow velocity were negatively correlated (r = - 0.41, p = 0.0195).

CONCLUSIONS

Delayed fluorescence appearance on ICG-FI was associated with reduced VC-derived microvascular flow velocity. To our knowledge, this is the first study to integrate ICG-FI and VC intraoperatively for quantitative assessment of intestinal perfusion. Combined ICG-FI and VC assessment may provide physiological support for interpreting delayed fluorescence as a potential marker of microcirculatory impairment. Further validation is required to determine its clinical utility.

Для цитирования: Iseki Sadahito, Aoki Takeshi, Watanabe Makoto, Watanabe Ryohei, Kitajima Tetsuya, Oura Keisuke, Miyasaka Shun, Uchida Yusuke, Sekiguchi Koya, Ohira Yasuyuki, Tomioka Kodai, Shibata Hideki, Tashiro Yoshihiko, Nogaki Koji, Date Hiromi, Matsuda Kazuhiro, Yamazaki Kimiyasu, Yamaue Hiroki, Yamochi Toshiko. A novel real-time assessment of intestinal perfusion with dual imaging using ICG fluorescence and capillaroscopy in colorectal surgery.. Langenbeck's archives of surgery. 2026. DOI: 10.1007/s00423-026-04094-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.