MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.1243

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2001

Platypnea-orthodeoxia: management by transcatheter buttoned device implantation.

Rao P S, Palacios I F, Bach R G, Bitar S R, Sideris E B

СтатьяПеревод в очереди

Аннотация

Dyspnea and arterial desaturation on upright position in elderly subjects is described as platypnea-orthodeoxia syndrome (POS) and in some patients it is due to right-to-left shunt across the atrial septal defect (ASD)/patent foramen ovale (PFO). Surgical closure of ASD/PFO has been the only available treatment option. Buttoned device has been used for occlusion of ostium secundum ASD, PFO associated with presumed paradoxical embolism and cerebrovascular accidents and ASD/PFO in association with other congenital heart defects causing right-to-left shunt. The objective of this article is to describe the use of buttoned device in effectively occluding ASD/PFO to relieve hypoxemia of POS. During a 4-year period ending January 2000, 10 patients, ages 71 +/- 9 (range 60-83) years with POS underwent buttoned device closure of their ASD/PFO. Echocardiographic and balloon-stretched atrial defect sizes were 8 +/- 3 mm and 12 +/- 3 mm, respectively. The ASD/PFO were occluded with devices ranging in size from 25 to 40 mm delivered via 9 French, long, blue Cook sheaths; eight had an additional 25- or 35-mm occluder placed on the right atrial side. The oxygen saturation increased (P < 0.001) from 76 +/- 7% (range 69-86%) to 95 +/- 2% (range 92-98%). No complications were encountered. Relief of symptoms was seen in all patients. Follow-up of 1-36 months (median 12 months) revealed persistent improvement of symptoms. Buttoned device occlusion of ASD/PFO to relieve hypoxemia of POS is feasible, safe, and effective and is an excellent alternative to surgery. Cathet Cardiovasc Intervent 2001;54:77-82.

Для цитирования: Rao P S, Palacios I F, Bach R G, Bitar S R, Sideris E B. Platypnea-orthodeoxia: management by transcatheter buttoned device implantation.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2001. DOI: 10.1002/ccd.1243.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.