MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1365-2125.2007.03004.x

Медицинская библиотека · British journal of clinical pharmacology · 2007

A comparison of serum antivenom concentrations after intravenous and intramuscular administration of redback (widow) spider antivenom.

Isbister Geoffrey K, O'Leary Margaret, Miller Mark, Brown Simon G A, Ramasamy Sharmaine, James Rosemary, Schneider Jennifer S

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIMS: There are no studies measuring antivenom concentrations following intramuscular administration. This study aimed to compare antivenom concentrations following intravenous and intramuscular administration of redback spider antivenom (RBSAV).

METHODS

Twenty patients recruited to a controlled trial comparing intramuscular and intravenous administration of antivenom had serial blood samples collected at 30 min intervals for 2 h after the administration of one or two doses of antivenom. Antivenom concentration was measured using an enzyme immunoassay.

RESULTS

Ten patients received intramuscular antivenom but antivenom could not be detected in serum after either one or two vials, at any time point. The median time of the final sample after commencement of antivenom treatment in these patients was 3.2 h (1.8-5 h). Ten patients received intravenous antivenom (three one vial and seven two or more vials) and antivenom was detected in all patients.

CONCLUSIONS

RBS AV given by the intramuscular route is unlikely to be effective in the treatment of redback (widow) spider bite.

Для цитирования: Isbister Geoffrey K, O'Leary Margaret, Miller Mark, Brown Simon G A, Ramasamy Sharmaine, James Rosemary, Schneider Jennifer S. A comparison of serum antivenom concentrations after intravenous and intramuscular administration of redback (widow) spider antivenom.. British journal of clinical pharmacology. 2007. DOI: 10.1111/j.1365-2125.2007.03004.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.