DOI 10.3389/fonc.2025.1503131

Медицинская библиотека · Frontiers in oncology · 2025

Impact of heart motion on radiation dose in the heart and left ventricular myocardium during breast cancer treatment.

Xiao Zhiqing, Wang Yanqiang, Wang Miao, Guo Han, Lin Xiaotong, Tian Lei, Liu Junling, Li Xiuwu, Xue Xiaoying

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study aimed to investigate changes in the geometric position and dosimetry differences of the heart and the left anterior descending coronary artery (LAD) during radiotherapy with deep inspiration breath hold (DIBH) in patients with left-sided breast cancer after radical mastectomy.

METHODS

A retrospective analysis was undertaken on 10 patients with left-sided breast cancer who received DIBH radiotherapy. Changes in the motion position of the heart and the LAD and dosimetric differences were compared by analyzing the planning CT and cone beam CT (CBCT) images.

RESULTS

Heart volume was negatively correlated with the heart V 5 and D mean and positively correlated with V 30 and D max. Changes in the heart volume were positively correlated with the dose changes in both the heart and the LAD. The lateral (X-axis) motion of the heart was positively correlated with the heart V 15 and V 20 and the LAD D max, but negatively correlated with the heart D max. Superior-inferior (Y-axis) motion was negatively correlated with the heart V 15, V 20, V 30, and D mean and changes in the LAD dose. Anterior-posterior (Z-axis) motion was positively correlated with changes in both the heart dose and the LAD V 5, V 15, and V 20 doses. Owing to alterations in the centroids, the heart requires expansions of the planning margins of 1.33, 4.10, and 2.42 mm in the X, Y, and Z directions, respectively, while the LAD requires expansions of 3.13, 1.79, and 5.43 mm in the corresponding directions. The distances of the cardiac boundary boxes during the different sessions showed a positive correlation with the heart V 5, V 15, V 20, V 30, and D mean and a negative correlation with the LAD V 5 and D max.

CONCLUSIONS

During the implementation of DIBH radiotherapy for the treatment of left-sided breast cancer, dose assessment for the heart and the LAD provided by static CT planning may contain some inaccuracies. Accordingly, it is recommended to reasonably adjust the organ-at-risk external boundaries in the treatment plan to effectively control the doses received by the heart and the LAD, thereby ensuring patient safety.

Для цитирования: Xiao Zhiqing, Wang Yanqiang, Wang Miao, Guo Han, Lin Xiaotong, Tian Lei, Liu Junling, Li Xiuwu, Xue Xiaoying. Impact of heart motion on radiation dose in the heart and left ventricular myocardium during breast cancer treatment.. Frontiers in oncology. 2025. DOI: 10.3389/fonc.2025.1503131.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.