The biomechanical analysis of three-dimensional distal radius fracture model with different fixed splints.

Hua Zhen, Wang Jian-Wei, Lu Zhen-Fei, Ma Jian-Wei, Yin Heng

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The distal radius fracture is one of the common clinical fractures. At present, there are no reports regarding application of the finite element method in studying the mechanism of Colles fracture and the biomechanical behavior when using splint fixation.

OBJECTIVE

To explore the mechanism of Colles fracture and the biomechanical behavior when using different fixed splints.

METHODS

Based on the CT scanning images of forearm for a young female volunteer, by using model construction technology combined with RPOE and ANSYS software, a 3-D distal radius fracture forearm finite element model with a real shape and bioactive materials is built. The material tests are performed to obtain the mechanical properties of the paper-based splint, the willow splint and the anatomical splint. The numerical results are compared with the experimental results to verify the correctness of the presented model. Based on the verified model, the stress distribution of different tissues are analyzed. Finally, the clinical tests are performed to observe and verify that the anatomical splint is the best fit for human body.

RESULTS

Using the three kinds of splints, the transferred bone stress focus on the distal radius and ulna, which is helpful to maintain the stability of fracture. Also the stress is accumulated in the distal radius which may be attributed to flexion position. Such stress distribution may be helpful to maintain the ulnar declination. By comparing the simulation results with the experimental observations, the anatomical splint has the best fitting to the limb, which can effectively avoid the local compression.

CONCLUSION

The anatomical splint is the most effective for fixing and curing the fracture. The presented model can provide theoretical basis and technical guide for further investigating mechanism of distal radius fracture and clinical application of anatomical splint.

Для цитирования: Hua Zhen, Wang Jian-Wei, Lu Zhen-Fei, Ma Jian-Wei, Yin Heng. The biomechanical analysis of three-dimensional distal radius fracture model with different fixed splints.. Technology and health care : official journal of the European Society for Engineering and Medicine. 2018. DOI: 10.3233/thc-171050.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.