MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jch.12864

Медицинская библиотека · Journal of clinical hypertension (Greenwich, Conn.) · 2016

Strict Blood Pressure Control Achieved Using an ICT-Based Home Blood Pressure Monitoring System in a Catastrophically Damaged Area After a Disaster.

Nishizawa Masafumi, Hoshide Satoshi, Okawara Yukie, Matsuo Takefumi, Kario Kazuomi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

At the time of the Great East Japan earthquake and tsunami (March 2011), the authors developed a web-based information and communications technology (ICT)-based blood pressure (BP) monitoring system (the Disaster CArdiovascular Prevention [DCAP] Network) and introduced it in an area that was catastrophically damaged (Minamisanriku town) to help control the survivors' BP. Using this system, home BP (HBP) was monitored and the data were automatically transmitted to a central computer database and to the survivors' attending physicians. The study participants, 341 hypertensive patients, continued to use this system for 4 years after the disaster and all of the obtained HBP readings were analyzed. This DCAP HBP-guided approach helped achieve a decrease in the participants' HBPs (initial average: 151.3±20.0/86.9±10.2 mm Hg to 120.2±12.1/70.8±10.2 mm Hg) over the 4 years. In addition, the amplitude of seasonal BP variation was suppressed and the duration from the summer lowest HBP values to the winter peak HBP values was gradually prolonged. This ICT-based approach was useful to achieve strict HBP control and minimize the seasonal BP variation even in a catastrophically damaged area during a 4-year period after the disaster, suggesting that this approach could be a routine way to monitor BP in the community.

Для цитирования: Nishizawa Masafumi, Hoshide Satoshi, Okawara Yukie, Matsuo Takefumi, Kario Kazuomi. Strict Blood Pressure Control Achieved Using an ICT-Based Home Blood Pressure Monitoring System in a Catastrophically Damaged Area After a Disaster.. Journal of clinical hypertension (Greenwich, Conn.). 2016. DOI: 10.1111/jch.12864.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.