Accuracy of antibiotic concentrations in drug dispensing in neonates: a laboratory-based study.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zheng Li-Yuan, Gu Wei-Ping, Liang Na, Gao Li-Li, Guo Wen-Wen, Li Rui-Rui, Wang Xin, Hao Guo-Xiang, Van Den Anker John, Wu Yue-E, Zhao Wei

Аннотация

BACKGROUND: Antibacterial therapy plays a crucial role in neonatal infections. The efficacy of antibacterial agents is closely related to the actual dose given to neonates. So we evaluated factors potentially affecting the actual dose of intravenous antibiotics during dispensing process in neonates.

METHODS: Meropenem, cefoperazone/sulbactam and piperacillin/tazobactam with two strengths were used to evaluate three methods. Method A (MA) was diluted once and the volumes of 5% glucose for MA were meropenem 4.00 mL, cefoperazone/sulbactam 3.00 mL, piperacillin/tazobactam 9.00 mL. Method B (MB) differed by doubling the volume of 5% glucose. The difference in method C (MC) involved diluting with 5% glucose twice. The concentrations were measured by high-performance liquid chromatography. Relative error (RE) was used to evaluate the preparation accuracy.

RESULTS: The RE values using MA/MB/MC were: (1) meropenem 0.5 g: 15.1%, 8.0%, 10.4%; 0.25 g: 7.8%, 3.1%, 6.0%; (2) cefoperazone/sulbactam 1.5 g: 13.6%, 4.2%, 3.4%; 0.75 g: 8.8%, 3.5%, 4.0%; (3) piperacillin/tazobactam 4.5 g: 18.2%, 8.7%, 6.3%; 562.5 mg: 8.1%, 2.8%, 6.1%. MB was better than MA in all three drugs. No difference in RE values was found between single and double dilution, except meropenem with 0.25 g. Using MB, meropenem and piperacillin/tazobactam with small drug strength had higher accuracy in preparation.

CONCLUSIONS: MB was suitable for neonatal drug dispensing because of its high accuracy and simple operation. Drugs with small strength were promoted due to the high accuracy.