MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/bjs/znaf279

Медицинская библиотека · The British journal of surgery · 2025

Outcomes of endovascular aortic arch repair with an off-the-shelf modular inner branched stent-graft: an IDEAL 2a prospective multicentre trial.

Guo Wei, Rong Dan, Zhang Hongkun, Zhang Leiyang, Zhuang Hui, Peng Hua, Wu Xuejun, Gong Kunmei, Wang Wei, Li Zhen, Fu Weiguo, Zhang Xiaoming, Guo Mingjin, Chang Guangqi, Dai Xiangchen, Zuo Jian, Guo Yingqiang, Chen Bing, Zhang Lei, Zhang Taoran, Zhang Hongpeng

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Aortic arch pathologies are complex to treat. Alternatives include open surgery, hybrid surgery (endovascular aortic stent-grafting and open surgical debranching procedures) and total endovascular solutions with branched stent-grafts. Branched stent-grafts are the mainstream approach for endovascular repair, but they are primarily available only as dedicated custom-made devices. The aim of this study was to evaluate the safety and effectiveness of a non-customized modular aortic arch stent-graft.

METHOD: This trial was led by the Chinese PLA General Hospital and 16 additional aortic centres in China. All included patients were treated with a non-customized modular inner branched stent-graft (Endonom Medtech, Hangzhou, China). The study endpoints were 30-day death and stroke, technical success, clinical success, early and late complications, reintervention, and death during follow-up. Follow-up via clinical examination and CT angiography scan were scheduled post surgery at 1, 6, and 12 months, and annually thereafter.

RESULTS

From June 2021 to December 2024, a total of 88 patients were enrolled in this study. Technical success rate was 100%. The mean follow-up was 28.6 ± 11.7 months. The overall 30-day mortality rate was 3%, and the 30-day stroke rate was 9%. Overall survival was 91% ± 3%, 86% ± 4%, and 81% ± 4% at 12, 24, and 36 months respectively. A total of 10 patients developed endoleaks, none of which required reintervention.

CONCLUSION

Modular branched stent-graft repair for aortic arch disease is feasible and with comparative rates of safety with custom made branched endovascular stent-grafts, hybrid techniques and open surgery. Long-term comparative effectiveness studies are required to establish whether it is superior to alternative interventions.

Для цитирования: Guo Wei, Rong Dan, Zhang Hongkun, Zhang Leiyang, Zhuang Hui, Peng Hua, Wu Xuejun, Gong Kunmei, Wang Wei, Li Zhen, Fu Weiguo, Zhang Xiaoming, Guo Mingjin, Chang Guangqi, Dai Xiangchen, Zuo Jian, Guo Yingqiang, Chen Bing, Zhang Lei, Zhang Taoran, Zhang Hongpeng. Outcomes of endovascular aortic arch repair with an off-the-shelf modular inner branched stent-graft: an IDEAL 2a prospective multicentre trial.. The British journal of surgery. 2025. DOI: 10.1093/bjs/znaf279.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.