MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Journal of surgical orthopaedic advances · 2020

Infections Associated with Temporary External Fixation.

Salar Mohamed, Dougherty Paul J

СтатьяПеревод в очереди

Аннотация

Infections associated with external fixation are thought to be related to the fixator construct, the length of time a fixator is on the limb and the injury severity score (ISS). Patients who had temporary external fixation applied for lower extremity fractures were included. Charts were reviewed for prevalence of infection, loss of reduction or other external fixator modification. Other variables were length of time the fixator was applied and the length of hospitalization. Seventy-five patients with 80 fractures met our study criteria. Of 80 fractures, 23 (28.8%) were associated with infection at the fracture site. Average time to conversion from external fixation to definitive fixation was 13.23 ± 19.8 for infected fractures and 20.03 ± 17.08 (p = 0.137) for those without infection. We did not find that the length of time a fixator was applied was associated with an increased infection rate of the fracture site, the pin sites or other regions. (Journal of Surgical Orthopaedic Advances 29(2):73-76, 2020).

Для цитирования: Salar Mohamed, Dougherty Paul J. Infections Associated with Temporary External Fixation.. Journal of surgical orthopaedic advances. 2020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.