OBJECTIVES

We quantified viable hepatocyte-like cells (HLCs) administered via portal or tail veins in the livers and lungs of immunodeficient rats using real-time reverse transcription polymerase chain reaction (RT-PCR) and human glyceraldehyde 3-phosphate dehydrogenase (GAPDH) primers.

METHODS

Immunodeficient rats were infused with HLCs via portal or tail veins. mRNA was quantified based on the route of cell administration and the presence of liver injury.

RESULTS

Human-specific GAPDH mRNA primers detected 0.1 pg human RNA in 100 ng (1:106) of rat liver RNA. When infused into the portal vein, the quantity of HLC mRNA reduced to 5% 3 h after infusion. Most HLCs were entrapped in the lungs when infused via the tail vein and decreased to approximately 10% 6 h after infusion. A small number of HLCs made it to the liver but disappeared rapidly, regardless of liver injury. 24 h after infusion, viable HLCs were detected only in the lungs of rats with liver injury (P < 0.05).

CONCLUSIONS

The quantity of viable human cells in immunodeficient rats was estimated using real-time RT-PCR and primers specific to human mRNA.

Для цитирования: Shimamura Naohiro, Fujii Kazuyuki, Ohkoshi Shogo. Detection and quantification of human-specific mRNA from hepatocyte-like cells derived from dental pulp using real-time polymerase chain reaction.. Journal of oral biosciences. 2021. DOI: 10.1016/j.job.2021.07.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.