Cuff leak test and laryngeal survey for predicting post-extubation stridor.
Аннотация
BACKGROUND AND AIMS: Evidence for the predictive value of the cuff leak test (CLT) for post-extubation stridor (PES) is conflicting. We evaluated the association and accuracy of CLT alone or combined with other laryngeal parameters with PES.
METHODS
Fifty-one mechanically ventilated adult patients in a medical-surgical intensive care unit were tested prior to extubation using; CLT, laryngeal ultrasound and indirect laryngoscopy. Biometric, laryngeal and endotracheal tube (ETT) parameters were recorded.
RESULTS
PES incidence was 4%. CLT demonstrated 'no leak' in 20% of patients. Laryngeal oedema was present in 10% of the patients on indirect laryngoscopy, and 71% of the patients had a Grades 1-3 indirect laryngoscopic view. Mean air column width on laryngeal ultrasound was 0.66 ± 0.15 cm (cuff deflated), mean ratio of ETT to laryngeal diameter was 0.48 ± 0.07, and the calculated CLT and laryngeal survey composite was 0.86 ± 1.25 (range 0-5). CLT and the CLT and Laryngeal survey composite measure were not associated with or predict PES. Age, sex, peri-extubation steroid use, intubation duration and body mass index were not associated with PES.
CONCLUSION
Even including ultrasonographic and indirect laryngoscopic examination of the airway, no single aspect of the CLT or combination with laryngeal parameters accurately predicts PES.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.