Sexually transmitted infections · 2018

Molecular test for chlamydia and gonorrhoea used at point of care in remote primary healthcare settings: a diagnostic test evaluation.

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Causer Louise M, Guy Rebecca J, Tabrizi Sepehr N, Whiley David M, Speers David John, Ward James, Tangey Annie, Badman Steven G, Hengel Belinda, Natoli Lisa Jane, Anderson David A, Wand Handan, Wilson David, Regan David G, Shephard Mark, Donovan Basil, Fairley Christopher K, Kaldor John M

Аннотация

OBJECTIVES: A new molecular test for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) (GeneXpert CT/NG) has been demonstrated to be as accurate as conventional nucleic acid amplification tests (NAAT), but performance has not been evaluated in routine primary care, performed at the point of care by clinicians. We aimed to examine its diagnostic performance when used by clinicians in remote community health services in Australia with high prevalences of CT and NG infection. The trial was registered with the Australian and New Zealand Clinical Trials Registry (#12613000808741) METHODS: At 12 health services, training was provided to 99 clinicians in the use of the GeneXpert CT/NG assay who tested specimens from all patients undergoing STI screening. Specimens were also sent in parallel for conventional laboratory-based NAATs and the concordance of results was evaluated.

RESULTS: Clinicians conducted 2486 tests: CT concordance was 99.4% (95% CI 99.1 to 99.7) with a positive concordance of 98.6% (95% CI 95.9 to 99.7) and negative concordance of 99.5% (95% CI 99.1 to 99.8); NG concordance was 99.9% (95% CI 99.7 to 100.0) with a positive concordance of 100.0% (95% CI 97.5 to 100.0) and negative concordance of 99.9% (95% CI 99.7 to 100.0).

CONCLUSIONS: In this first study reporting routine point-of-care use of GeneXpert CT/NG by primary care clinicians, we found excellent concordance with conventional NAATs. The use of the GeneXpert CT/NG at the point of care could potentially transform management and control of these infections in many endemic settings, including low/middle-income countries.