MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00216-020-02845-9

Медицинская библиотека · Analytical and bioanalytical chemistry · 2020

An improved drop casting electrochemical strategy for furosemide quantification in natural waters exploiting chemically reduced graphene oxide on glassy carbon electrodes.

Vasconcelos Sancler C, Rodrigues Eduardo M, de Almeida Leonardo G, Lepri Fábio G, Pacheco Wagner F, Semaan Felipe S, Dornellas Rafael M

СтатьяПеревод в очереди

Аннотация

This work exploits the applicability of a chemically reduced graphene oxide (CRGO) modification on the electrochemical response of a glassy carbon electrode (GCE) for the first-time sensitive determination of furosemide in natural waters. The batch injection analysis (BIA) is proposed as an analytical method, where CRGO-GCE is coupled to a BIA cell for amperometric measurements. Acetate buffer (0.1 μmol L-1, pH 5.2) was used as the background electrolyte. The modification provided an increase in sensitivity (0.024 μA/μmol L-1), low limit of detection (0.7 μmol L-1), RSD (< 4%), and broad linear range (1-600 μmol L-1). Recovery tests performed in two different concentration ranges resulted in values between 89 and 99%. Recovery tests were performed and compared with high-performance liquid chromatography (HPLC) with UV-Vis detection using Student's t test at a 95% significance level, and no significant differences were found, confirming the accuracy of the method. The developed method is proven faster (169 h-1) compared with the HPLC analysis (5 h-1), also comparable with other flow procedures hereby described, offering a low-cost strategy suitable to quantify an emerging pharmaceutical pollutant. Graphical abstract.

Для цитирования: Vasconcelos Sancler C, Rodrigues Eduardo M, de Almeida Leonardo G, Lepri Fábio G, Pacheco Wagner F, Semaan Felipe S, Dornellas Rafael M. An improved drop casting electrochemical strategy for furosemide quantification in natural waters exploiting chemically reduced graphene oxide on glassy carbon electrodes.. Analytical and bioanalytical chemistry. 2020. DOI: 10.1007/s00216-020-02845-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.