DOI 10.1016/j.jelectrocard.2026.154273
Comparison of measured and synthesized right-sided precordial electrocardiograms in patients with right ventricular infarction.
Аннотация
BACKGROUND
Right-sided chest precordial electrocardiogram (ECG) leads (V3R-V5R) are critical for diagnosing right ventricular (RV) infarction complicating acute inferior wall myocardial infarction. However, obtaining these leads in emergency settings can be time-consuming. This study compared measured and synthesized right-sided precordial ECGs to determine whether a synthesized ECG derived from a standard 12‑lead tracing can serve as a reliable alternative.
METHODS
We retrospectively analyzed 38 patients (admitted between 2016 and 2024) with acute inferior wall myocardial infarction who underwent both measured and synthesized right-sided precordial ECGs. ST-segment deviation from the isoelectric line was quantified at the ST junction (STJ), at 40 ms (ST1), and 80 ms (ST2) thereafter for V3R-V5R. Agreement was evaluated using Pearson's correlation, Bland-Altman analysis, and receiver-operating-characteristic (ROC) curve analysis for the detection of RV infarction (ST elevation ≥0.1 mV in V4R).
RESULTS
Pearson's r for measured versus synthesized ECGs was 0.90 for V3R, 0.84 for V4R, and 0.78 for V5R (all P < 0.001). Bland-Altman plots showed negligible bias (mean difference ≤ 0.02 mV) with narrow 95% limits of agreement (∼ ± 0.12 mV). Diagnostic performance was equivalent between synthesized and measured V4R (ΔAUC = 0.0028; SE = 0.0551; 95% CI -0.105 to 0.111; z = 0.0505; P = 0.9598).
CONCLUSIONS
Synthesized right-sided precordial ECGs derived from a standard 12‑lead tracing closely reproduce measured leads in acute inferior wall myocardial infarction and may enable rapid identification of RV infarction without delaying reperfusion therapy.