MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ccm.0b013e3182a667f0

Медицинская библиотека · Critical care medicine · 2014

Central venous catheter placement by advanced practice nurses demonstrates low procedural complication and infection rates--a report from 13 years of service*.

Alexandrou Evan, Spencer Timothy R, Frost Steven A, Mifflin Nicholas, Davidson Patricia M, Hillman Ken M

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To report procedural characteristics and outcomes from a central venous catheter placement service operated by advanced practice nurses.

DESIGN

Single-center observational study.

SETTING

A tertiary care university hospital in Sydney, Australia.

PATIENTS: Adult patients from the general wards and from critical care areas receiving a central venous catheter, peripherally inserted central catheter, high-flow dialysis catheter, or midline catheter for parenteral therapy between November 1996 and December 2009.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN

RESULTS

Prevalence rates by indication, site, and catheter type were assessed. Nonparametric tests were used to calculate differences in outcomes for categorical data. Catheter infection rates were determined per 1,000 catheter days after derivation of the denominator. A total of 4,560 catheters were placed in 3,447 patients. The most common catheters inserted were single-lumen peripherally inserted central catheters (n = 1,653; 36.3%) and single-lumen central venous catheters (n = 1,233; 27.0%). A small proportion of high-flow dialysis catheters were also inserted over the reporting period (n = 150; 3.5%). Sixty-one percent of all catheters placed were for antibiotic administration. The median device dwell time (in d) differed across cannulation sites (p < 0.001). Subclavian catheter placement had the longest dwell time with a median of 16 days (interquartile range, 8-26 d). Overall catheter dwell was reported at a cumulative 63,071 catheter days. The overall catheter-related bloodstream infection rate was 0.2 per 1,000 catheter days. The prevalence rate of pneumothorax recorded was 0.4%, and accidental arterial puncture (simple puncture-with no dilation or cannulation) was 1.3% using the subclavian vein.

CONCLUSIONS

This report has demonstrated low complication rates for a hospital-wide service delivered by advance practice nurses. The results suggest that a centrally based service with specifically trained operators can be beneficial by potentially improving patient safety and promoting organizational efficiencies.

Для цитирования: Alexandrou Evan, Spencer Timothy R, Frost Steven A, Mifflin Nicholas, Davidson Patricia M, Hillman Ken M. Central venous catheter placement by advanced practice nurses demonstrates low procedural complication and infection rates--a report from 13 years of service*.. Critical care medicine. 2014. DOI: 10.1097/ccm.0b013e3182a667f0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…