m+Medelevator.RU
← Поиск публикаций
Nuklearmedizin. Nuclear medicine · 2010

18F-FDG-PET and MRI in patients with malignancies of the liver and pancreas. Accuracy of retrospective multimodality image registration by using the CT-component of PET/CT.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zheng Mianfeng, Huang Lixin, Yuan Haitao, Li Zhuoya, Wang Yi, Su Yangjing, Deng Zhixin, Chen Ali, Zhao Weiguo, Wang Weiming, Xiao Wei

Аннотация

PURPOSE: To evaluate the accuracy of retrospective rigid image registration and fusion between F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and magnetic resonance imaging (MRI) of the upper abdomen.

PATIENTS, MATERIAL, METHODS: Image fusion of PET and MRI was performed in 30 patients with suspected malignancy of the liver or pancreas. Using a commercially available image fusion tool capable of rigid manual point-based registration, PET-Images were retrospectively registered and fused by matching eight homologous points in the 3D spoiled gradient echo (GRE) MRI sequences acquired in portal venous phase and in the CT-component of PET/CT. Two separate observers (R1, R2) assessed accuracy of image registration by determining the distances in the x-, y- and z-axis as well as the absolute distance between anatomical landmarks which differed from the landmarks chosen for registration. Quality of fusion was graded using a three point grading scale (1 poorly fused; 2 satisfactory fused; 3 correctly fused) and compared to hybrid PET/CT fusion.

RESULTS: Mean time of registration per patient was less than 2 minutes. Objective registration assessment showed errors between 2.4-6.3 mm in x-axis: mean 3.6 mm (R1); 4.6 mm (R2), 2.3-9.3 mm in y-axis (mean 5.1 mm; 5.5 mm) and 3.3-12.0 mm in z-axis (mean 5.9 mm; 5.9 mm.) The mean error in absolute distance between points was 6.0-16.8 mm (mean 9.9 mm; 10.6 mm). In visual assessment, most fusions were graded to be satisfactory or correctly fused: R1, R2: grade 3, 11/30 (36.7%), 22/30 (73.3%); grade 2, 13/30 (43.3%), 8/30 (26.7%); grade 1, 6/30 (20%), 0/30 (0%). Fusions were mostly comparable to hybrid PET/CT fusions. All of the fusions were defined as diagnostically relevant by both observers.

CONCLUSION: Retrospective rigid image fusion of FDG-PET and MRI of the upper abdomen using the CT-component of PET/CT for registration is feasible without adaptation in image acquisition protocols and shows sub-centimeter registration errors in most cases.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты