Jugular versus femoral short-term catheterization and risk of infection in intensive care unit patients. Causal analysis of two randomized trials.

Timsit Jean-François, Bouadma Lila, Mimoz Olivier, Parienti Jean-Jacques, Garrouste-Orgeas Maïté, Alfandari Serge, Plantefeve Gaétan, Bronchard Régis, Troche Gilles, Gauzit Remy, Antona Marion, Canet Emmanuel, Bohe Julien, Herrault Marie-Christine, Schwebel Carole, Ruckly Stéphane, Souweine Bertrand, Lucet Jean-Christophe

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод в очереди

Аннотация

RATIONALE: When subclavian access is not possible, controversy exists between the internal jugular and femoral sites for the choice of central-venous access in intensive care unit patients.

OBJECTIVES

To compare infection and colonization rates of short-term jugular and femoral catheters.

METHODS

Using data from two multicenter studies, we compared femoral and internal jugular for the risks of catheter-related bloodstream infection, major catheter-related infection, and catheter-tip colonization. We also compared the rates of dressing disruption and skin colonization. We used marginal structural models with inverse probability of treatment weighting to adjust on indication bias.

MEASUREMENTS AND MAIN

RESULTS

We included 2,128 patients (2,527 catheters and 19,481 catheter-days). We found no difference in catheter-related bloodstream infection (internal jugular 1.0 vs. femoral 1.1 per 1,000 catheter-days; hazard ratio [HR], 0.63 [0.25-1.63]; P = 0.34), major catheter-related infection (internal jugular 1.8 vs. femoral 1.4 per 1,000 catheter-days; HR, 0.91 [0.38-2.18]; P = 0.34), and colonization (internal jugular 11.6 vs. femoral 12.9 per 1,000 catheter-days; HR, 0.80 [0.25-1.63]; P = 0.15). However, colonization was higher with femoral for female (HR, 0.39 [0.24-0.63]; P < 0.001) and, at the significance limit, catheter maintained for more than 4 days (HR, 0.73 [0.53-1.01]; P = 0.05). The absence of benefit of internal jugular before Day 5 was related to a higher skin colonization at the internal jugular site for catheters removed before Day 5. After the fourth day, dressing disruption became more frequent with femoral catheters and may explain the subsequent risk of catheter colonization. Differences in cutaneous and catheter colonization between internal jugular and femoral was suppressed by the use of chlorhexidine-impregnated dressings.

CONCLUSIONS

Femoral and internal jugular accesses lead to similar risks of catheter infection. Internal jugular might be preferred for female, nonchlorhexidine-impregnated dressings users, and when catheters are left in place more than 4 days. Both sites are acceptable when a subclavian approach is not feasible. Clinical trial registered with www.clinicaltrials.gov (NCT00417235 and NCT01189682).

Для цитирования: Timsit Jean-François, Bouadma Lila, Mimoz Olivier, Parienti Jean-Jacques, Garrouste-Orgeas Maïté, Alfandari Serge, Plantefeve Gaétan, Bronchard Régis, Troche Gilles, Gauzit Remy, Antona Marion, Canet Emmanuel, Bohe Julien, Herrault Marie-Christine, Schwebel Carole, Ruckly Stéphane, Souweine Bertrand, Lucet Jean-Christophe. Jugular versus femoral short-term catheterization and risk of infection in intensive care unit patients. Causal analysis of two randomized trials.. American journal of respiratory and critical care medicine. 2013. DOI: 10.1164/rccm.201303-0460oc.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.